background image

2

PIR BOARD LAYOUT

1. LED:

 When an intrusion is detected, the LED will activate.

2. JP1: 

Pulse count setting.

 

1-2 short:

 Relay will activate when an intrusion is detected once. (For stable 

 

                  environments or high risk operating environments)

 

2-3 short: 

Relay will activate when an intrusion is detected twice within 15 seconds.

 

                  (For harsh environments)

3. JP2:

 Relay output select.

 

Short: 

For outer control used in area where DC12V is requested (Limited at 200mA).

  

Normal: 

N.C. = DC12V out

  

Activate: 

N.O. = DC12V out

 

Open: 

Normal relay connector (1.5A at DC24V/1.5A at AC120V/1A at AC240V)

  

Normal: 

C & N.C. short / C & N.O. open.

  

Activate: 

 C & N.C. open / C & N.O. short.

Caution! Risk of electric shock. Set-up and operation should be performed by 
Authorized Service Person only.

4. VR1: 

Sensitivity adjustment.

 

Turn clockwise for high sensitivity, turn counter-clockwise for low.

5. VR2: 

Relay activation time adjustment (range about 2 ~ 30 seconds).

 

Turn clockwise for short time, turn counter-clockwise for long.

6. NC/C/NO Wiring:

 

C: 

BLACK   

 NO: 

WHITE  

 NC: 

YELLOW

CN1 Connector:

1. DC 12V IN
2. GND
3. AUDIO OUT (option)
4. GND
5. VIDEO OUT
6. RELAY C. (common)
7. RELAY N.O. (normal open)
8. RELAY N.C. (normal close)

CN2 Connector:

1. AUDIO IN (Not Available In US)
2. VIDEO IN (from CCD MODULE)
3. GND
4. DC 12V/120mA OUT (for CCD MODULE)

Содержание VT-PIRC2/H

Страница 1: ...CD 960H with 700 TV Lines Minimum Illumination of 0 2 Lux 0 1 Lux Pinhole 3 7mm F2 0 Lens Included NC N NO Alarm Output Working 100 Motion Detection Using 58 Beams Within 3 layers 35 x 35 Coverage Area VT PIRC2 H Color PIR Cameras ...

Страница 2: ... at DC24V 1 5A at AC120V 1A at AC240V Normal C N C short C N O open Activate C N C open C N O short Caution Risk of electric shock Set up and operation should be performed by Authorized Service Person only 4 VR1 Sensitivity adjustment Turn clockwise for high sensitivity turn counter clockwise for low 5 VR2 Relay activation time adjustment range about 2 30 seconds Turn clockwise for short time turn...

Страница 3: ...erlace 0 45 15 734KHz H 60Hz V Composite 1 0 Vp p 75 Ohm 12VDC 100mA 10 60 C 14 140 F Less Than 80 RH 3 7mm F2 0 2 75 x 4 72 x 1 69 70mm x 120mm x 43mm SPECIFICATIONS VT PIRC2 H Use a professional CCTV monitor only to achieve best resolution and performance Camera may also be connected to other devices such as a DVR Use copper braid RG59U coax for best video performance Video may also be transmitt...

Страница 4: ...ds only to the original buyer or end user customer of a VITEK Authorized Reseller The product must have been used only for its intended purpose and not been subjected to damage by misuse willful or accidental damage caused by excessive voltage or lightning The product must not have been tampered with in any way or the guarantee will be considered null and void This guarantee does not affect your s...

Отзывы: