background image

5

ENGLISH

– 

Remove the HEPA filters (8) from the pack-

aging material.

– 

Insert the HEPA filters back into the tank.

– 

Install the upper unit part (1) on the tank (4).

Warning!  Before  filling  the  tank  with  water, 

switch the unit off and unplug it. Be careful not 

to get the unit body wet.

Note:  Use  the  unit  at  the  room  temperature 

between  +10°C  and  +40°C  and  the  relative 

humidity  less  than  80%.  The  used  water  tem-

perature should not be higher than +40°С.

USING THE AIR WASHER

– 

Remove the upper unit part (1).

– 

Remove the HEPA filters (8) from the tank (4). 

Soak the filters in water.

– 

Insert the soaked HEPA filters (8) back into 

the tank (4).

Warning!  The  filters  should  be  cleaned  regu-

larly, at least once a week. 

– 

Fill  the  tank  with  water  up  to  the  maximum 

level. Always use clean, cold tap water. Since 

water  quality  varies  by  region,  it  is  recom-

mended  to  use  distilled  or  filtered  water  to 

minimize the risk of contamination and calci-

fication (scale formation).

Warning! Do not exceed the maximum mark.

– 

Install  the  body  (1)  on  the  tank  (4).  If  you 

spill water, before switching the unit on, dry 

it  and  the  surfaces  where  water  has  been 

spilled, and make sure that all parts of the 

unit  and  the  surface,  on  which  the  unit  is 

placed, are dry.

– 

Connect the unit to the mains.

– 

Switch  the  unit  on  by  pressing  the  on  but-

ton (11). 

– 

When the unit is turned on, the built-in air ion-

izer is automatically activated.

– 

Set  the  unit  operating  modes  accord-

ing  to  your  preferences.  After  pressing 

the buttons (11), the LED indicator of the 

selected operation speed (12) will light up, 

to  change  the  selected  operation  speed, 

press the corresponding button again (the 

programming function will be deactivated 

after the successive switching of all three 

modes).

Timer setting

By  successively  pressing  the  button  (9)  «

», 

set the required timer operation time, while the 

LED  indicator  (10)  of  the  corresponding  mode 

will light up: 

 – corresponds to a 1-hour timer operation 

 – corresponds to a 2-hour timer operation 

 – corresponds to a 4-hour timer operation 

Humidity level setting

By  successively  pressing  the  button  (11)  «

»  

set the required operation speed, the LED indica-

tor (12) of the corresponding speed will light up: 

I – corresponds to low operation speed

II – corresponds to medium operation speed

III – corresponds to high operation speed.

– 

After using switch the unit off with the button 

(11) (the unit will be off after switching through 

all three humidity levels – after the «III» mark 

(intensive operation mode), the next press of 

the button will switch the unit off). 

– 

Unplug the unit.

Note!  This  unit  does  not  provide  an  auto-off 

function,  when  there  is  no  water  in  the  tank. 

Check for water in the tank periodically and top 

it up if necessary.

CLEANING AND CARE

– 

Switch off the unit and unplug it before clean-

ing.

– 

Do not use polish, gasoline or other chemical 

cleaners for cleaning.

– 

Wipe  the  cleaner  body  with  a  soft,  slightly 

damp cloth, then wipe it dry.

– 

Clean the air inlet and outlet air grids as they 

become dirty. 

– 

Fill the tank with water and rinse. Fill the tank 

with water and pour 2 tablespoons of vinegar 

into it. Leave the water with vinegar for about 

half an hour, then drain it and rinse the tank 

under the running water. You can also use a 

citric acid descaler to clean the tank.

Warning! Clean the water tank at least once a 

week.

– 

Wash the HEPA filters with cold running water 

and let them dry naturally. When washing, you 

can use a soft brush.

Warning!  The  HEPA  filters  should  be  cleaned 

regularly, at least once a week. 

Warning! Do not place the upper unit part under 

a tap or submerge it partially in water. Leaving 

the water in the tank for longer than a few days 

can cause bacterial growth, so the water should 

be replaced with fresh one every day.

STORAGE

– 

Before storing the unit, drain the water tank, 

remove the filters and let them dry naturally. 

Wipe  the  cleaner  body  and  the  tank  with  a 

soft, slightly damp cloth, then wipe them dry. 

Make sure the tank and the body are dry.

– 

Do not store the unit with water in the tank and 

with wet filters.

– 

Store the air cleaner in a dry cool place out of 

reach of children and disabled persons.

IM VT-8556.indd   5

8/25/20   3:18 PM

Содержание VT-8556

Страница 1: ...1 VT 8556 3 7 12 17 22 Air Washer IM VT 8556 indd 1 8 25 20 3 18 PM...

Страница 2: ...1 5 6 7 4 3 5 8 8 2 9 10 11 12 IM VT 8556 indd 2 8 25 20 3 18 PM...

Страница 3: ...ing the unit to the power supply check if the current and voltage of the mains correspond to the operating volt age and current of the unit Do not use the unit if the power cord or the power plug is d...

Страница 4: ...entilation openings people walls furniture wooden floors sockets or other electrical devices Do not place the unit on unprotected furni ture wooden floors etc Use for example a waterproof material to...

Страница 5: ...sponds to a 4 hour timer operation Humidity level setting By successively pressing the button 11 set the required operation speed the LED indica tor 12 of the corresponding speed will light up I corre...

Страница 6: ...y 220 240 V 50 60 Hz Rated input power 25 W Tank capacity 2 L Water discharge 120 150 ml h Ozone output less than 0 05 ppm Area serviced up to 25 m2 RECYCLING For environment protection do not throw o...

Страница 7: ...7 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III O3 HEPA 40 60 Rn www vitek ru IM VT 8556 indd 7 8 25 20 3 18 PM...

Страница 8: ...8 80 60 IM VT 8556 indd 8 8 25 20 3 18 PM...

Страница 9: ...9 50 60 1 HEPA 8 4 HEPA 8 HEPA 1 4 10 C 40 C 80 40 1 HEPA 8 4 HEPA 8 4 1 4 11 11 12 9 10 1 1 IM VT 8556 indd 9 8 25 20 3 18 PM...

Страница 10: ...10 2 2 4 4 11 12 I II III 11 III 2 HEPA HEPA 11 IM VT 8556 indd 10 8 25 20 3 18 PM...

Страница 11: ...240 50 60 25 2 120 150 0 05 25 2 info vitek ru 3 STAR PLUS LIMITED 15 38 117452 17 1 4 401 1 7 499 685 48 18 E MAIL info vitek ru 117452 17 1 4 401 1 www vitek ru 8 800 100 18 30 IM VT 8556 indd 11 8...

Страница 12: ...12 VT 8556 1 2 3 4 5 6 7 8 3 9 10 1 2 4 11 12 I II III O3 40 60 Rn www vitek ru IM VT 8556 indd 12 8 25 20 3 18 PM...

Страница 13: ...13 80 60 IM VT 8556 indd 13 8 25 20 3 18 PM...

Страница 14: ...14 50 60 1 8 4 8 1 4 10 C 40 C 80 40 1 8 4 8 4 1 4 11 11 IM VT 8556 indd 14 8 25 20 3 18 PM...

Страница 15: ...15 12 9 10 1 1 2 2 4 4 11 12 I II III 11 III 2 11 IM VT 8556 indd 15 8 25 20 3 18 PM...

Страница 16: ...16 12 1 1 220 240 50 60 25 2 120 150 0 05 25 info vitek ru 3 i i i i i i i i i i i i IM VT 8556 indd 16 8 25 20 3 18 PM...

Страница 17: ...17 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III 3 HEPA 40 60 Rn www vitek ru IM VT 8556 indd 17 8 25 20 3 18 PM...

Страница 18: ...18 80 60 IM VT 8556 indd 18 8 25 20 3 18 PM...

Страница 19: ...19 50 60 1 HEPA 8 4 HEPA 8 HEPA 1 4 10 C 40 C 80 40 1 HEPA 8 4 HEPA 8 4 1 4 11 11 12 9 IM VT 8556 indd 19 8 25 20 3 18 PM...

Страница 20: ...20 10 1 1 2 2 4 4 11 12 I II III 11 III 2 HEPA HEPA 11 IM VT 8556 indd 20 8 25 20 3 18 PM...

Страница 21: ...21 12 1 1 220 240 50 60 25 2 120 150 0 05 25 2 info vitek ru 3 2014 30 2014 35 IM VT 8556 indd 21 8 25 20 3 18 PM...

Страница 22: ...22 VT 8556 1 2 3 4 5 6 7 8 HEPA 3 9 10 1 2 4 11 12 I II III O3 40 60 Rn www vitek ru IM VT 8556 indd 22 8 25 20 3 18 PM...

Страница 23: ...23 80 60 IM VT 8556 indd 23 8 25 20 3 18 PM...

Страница 24: ...24 50 60 50 60 1 8 4 8 1 4 10 C 40 C 80 40 1 8 4 8 4 1 4 11 11 12 9 IM VT 8556 indd 24 8 25 20 3 18 PM...

Страница 25: ...25 10 1 1 2 2 4 4 11 12 I II III 11 III 2 11 IM VT 8556 indd 25 8 25 20 3 18 PM...

Страница 26: ...26 12 1 1 220 240 50 60 25 2 120 150 0 05 25 info vitek ru 3 IM VT 8556 indd 26 8 25 20 3 18 PM...

Страница 27: ...IM VT 8556 indd 27 8 25 20 3 18 PM...

Страница 28: ...late A serial number is an eleven unit number with the first four figures indicating the production date For example serial number 0606 means that the item was manufactured in June the sixth month 200...

Отзывы: