C O P Y O F O R I G I N A L M A N U A L – O S E - C 1 0 0 1
Release: 2012-06-04
VITECTOR GmbH
6 / 6
Carlswerkstr. 13c, D - 51063 Köln
Tel.: +49 (0) 221 - 9 62 13-0, T49 (0) 221 - 9 62 13-60, www.vitector.de, [email protected]
GB
Safety Properties
The safety properties are valid for the safety-related contacts (NC/COM). The non safety-related (NO/COM) does not
contain any safety category. The safety properties are valid for the combination of
OSE-C 1001, OSE-T 1100, OSE-R 1100 and OSE-C 1001, OSE-T 6521, OSE-R 6501. They do not include values of the
rubber profile.
Category
2 (EN 13849-1:2008)
Performance level
c (EN 13849-1:2008)
Maximum usage duration
20 years
MTTFd *)
47 years
PFH *)
3 x 10
-7
per hour
DC
90 %
Reaction time
16 ms
*) valid for B
10d
= 2 x 10
5
and N
op
≤
4 per hour
General Technical Data
Protection class
IP 65 (DIN VDE 0470)
Housing material
ABS, light grey similar. RAL 7035
Dimensions
width, high, lenght: 48,5 x 40 x 90 mm (without cable gland)
Operation position
any
Operating temperature
-20 °C to +55 °C
Supply voltage
24 V DC
±
20%
24 V AC +5/-35% 48-64 Hz
Power consumption
max. 2,5 W
Testing
Time to switch:
< 50 ms
Test activ:
0 V, max. 1 V
Function enabled:
24 V, +/- 20 %
Relay data
Output NC/COM and NO/COM
Switching voltage max.
120 V AC / 60 V DC ohmsche Last
Switching current max.
0,5 A, 120 V AC / 1 A, 24 V DC
Switching current min.
1 mA, 1 VDC
Fusing
0,5 A slow blowing (not part of unit)
Security advice
Only instructed persons are allowed to open the housing!
High voltage inside!