![Vitec Multimedia ProHD BR-DE800 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/vitec-multimedia/prohd-br-de800/prohd-br-de800_user-manual_1034959026.webp)
ProHD BR-DE800
Professional Decoder Appliance
User Manual, Version 2.5
24
For
PRO-MPEG
type
"3"
and enter the
IP address
and the
Port
number of the
streaming destination. To set the FEC Level A and B port numbers you have the two
following options:
* Either enter manually the FEC port numbers.
- Or -
* Use the standard default FEC port numbers by pressing Enter on your keyboard.
Standard default FEC port numbers will be automatically set according to the set
streaming port number as follows:
FEC Level A Port Number
= [<streaming destination port #> + (2)] e.g., when
the streaming destination port is
6504
, FEC Level A port number will be
6506
(see
figure below).
FEC Level B Port Number
= [<streaming destination port #> + (4)] e.g., when the
streaming destination port is
6504
, FEC Level B port number will be
6508
(see figure
below).
For
ZiXi,
type
"4"
and select whether you plan to use the ZiXi Broadcaster Server.
Push streaming method - when the streaming destination is the decoder IP address:
Enter the
Channel name =
the
Stream ID
on the ZiXi Broadcaster.
Enter the
Password
= the password on the ZiXi Broadcaster.
Enter the
Latency Value =
the
latency value that is set on the ZiXi Broadcaster.