PAGE 15

G. FREEZE PROTECTION

If the temperature in the spa plumbing falls
below 50º Fahrenheit (10º Celsius) the
water pump(s) will turn on soft-mode and
run for at least one minute. The display will
show 

“ICE”

. After one minute, if the water is

still below 50º F (10º Celsius), the heater
will turn on and raise the water temperature
10º F.

H. FLOW PROTECTION

If the flow of water through the heater 
is  insufficient,  the  spa  controller  will
automatically  turn  the  heater  off  to 
prevent overheating. The display will show

“FLO”

, indicating a flow restriction caused

by a clogged filter, shut gate valves or by 
a malfunction in the pressure switch. Call for
service if you cannot pinpoint the cause.

I.  OVERHEAT PROTECTION

If the water temperature inside the spa
reaches 110º F, the display will show 

“HILI”

(High Limit) and the heater will be disabled.
If the water temperature continues to rise
and reaches 118º F due to friction in the
pumps and plumbing system, the entire
system including all pumps will be disabled.
In 

“HILI”

condition,

DO NOT ENTER THE

WATER!

Remove the cover and allow the

water temperature to cool down to 104
degrees F.  Then reset the system by holding
down the 

“PROG”

button for 5 seconds.  If

the 

“HILI”

message returns, call for service.

K. H.E.E.T. PUMP

Each  spa  is  equipped  with  Vita  Spa’s
exclusive 

High Efficiency Energy Transfer

pump.  Similar  to  the  principle  of  heat
transfer  pumps,  the 

H . E . E . T.

s y s t e m

transfers  the  heat  generated  by  the
circulation pump motor to the water 24
hours a day. After the first twelve hours of
operation each day, as a protection against
overheating, the 

H.E.E.T

. pump will turn off

if  the  water  temperature  exceeds  the

desired  temperature.  The  4kw-system
heater will come back on when the water
temperature falls 1 degree F° under the
desired temperature.

L. SKIM–AWAY

S k i m – Away  is  an  automatic  skimming 
action  which  takes  place  each  day  from 
8am  until  8:30am  each  morning  and 
from  4pm  until  4:30pm  each  afternoon.
The  primary  pump  will  activate  in  high
speed mode.  This  will  pull  all  surface  oils
and debris into the filter well cavity.

M. REMOTE CONTROL

Your spa model may come equipped with a
remote control located on the opposite side
of the spa from the main spa side control.

The remote control will operate the jets,
blower, and light. It can not be used to
program the spa.

Содержание L700C Series

Страница 1: ...h e a l t h a n d r e l a x a t i o n f o r l i f e L700C LC500 SERIES OWNER S MANUAL VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Страница 2: ...ew any page better on smaller screens click on this button at the top of your Acrobat Reader Menu to switch to a closer view You can set your viewer s to always see the closer view in your preferences...

Страница 3: ...15 J H E E T Pump 15 K Skim Away 15 L Remote Control 15 Advanced Features 16 A Fahrenheit and Celsius Degrees 16 B Heat Days 16 Jet Operation 17 A Select A Swirl Jet 17 B Pulsator Jet 17 C Quad Stream...

Страница 4: ..._______________________________________ TELEPHONE ___________________________________________ SERIAL ______________________________________________ MODEL _____________________________________________...

Страница 5: ...nance We suggest that you take some time to carefully review it Please keep this manual available for reference If you have any questions regarding your Vita Spa set up operations or maintenance pleas...

Страница 6: ...or attached to the wire connector on the terminal box that is provided for this purpose National Electrical Code ANSI NMFP A70 1993 DANGER RISK OF ELECTRICAL SHOCK Do not permit any electrical applian...

Страница 7: ...r than normal body temperature can result in a dangerous condition known as HYPERTHERMIA The causes symptoms and effects of hyperthermia may be described as follows Hyperthermia occurs when the intern...

Страница 8: ...deliver the spa to its intended site MAINTENANCE Trees lawn placement surfaces etc can create extra work in keeping your spa area clean and safe Please be advised that placing your spa on dirt or gra...

Страница 9: ...arance for spa passage 3 TIGHT CORNERS Make sure there is space to maneuver 4 STORAGE SHEDS DOG HOUSES WOOD PILES Remove out of the way 5 GATES CLEARANCE FOR PASSAGE OF SPA Does gate need to be remove...

Страница 10: ...TO THE ROD SHOULD BE 6 BARE COPPER ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT THE INSTALLATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN 10 VISUAL FEET FROM THE SPA AND NOT LESS...

Страница 11: ...PAGE 7 COMMON NEUTRAL GROUND BAR IN MAIN SEPARATE NEUTRAL WEAK GROUND OR ROMEX WIRE USED TO FEED GFCI WITH UNDERSIZED GROUND WIRE...

Страница 12: ...PAGE 8 GFCI IN PANEL WITH SEPARATE NEUTRAL AND SOLID GROUND TO PANEL GFCI IN PANEL WITH COMMON NEUTRAL BAR AND OR ROMEX WITH UNDERSIZED WIRE USED TO FEED DISCONNECT...

Страница 13: ...9 GFCI MOUNTED IN PANEL AND DISCONNECT MOUNTED INSIDE TO COMMON WALL WITH METAL STUDS OR WITH METAL MOUNTING BOX GFCI IN PANEL WITH WEAK GROUND OR ROMEX WITH UNDERSIZED GROUND WIRE USED TO FEED DISCON...

Страница 14: ...ended The wire size for the distance of the wire run must conform to NEC and local electrical codes 5 To ensure proper connections use copper conductors only DO NOT USE ALUMINUM WIRE 6 The spas power...

Страница 15: ...own straps Utilizing the cover anytime the spa is not in use will reduce heat loss and thereby reduce the amount of running time required to make up that loss by the heating system Keep cover fastened...

Страница 16: ...select the current hour Press VIEW to show the minutes Press UP or DOWN to select the current minute NOTE To change current time at any time press the PROG button and then press the VIEW button twice...

Страница 17: ...ING TIME OR TEMPERATURE Pressing the VIEW button will switch the display between current time and current water temperature B TEMPORARILY ADJUSTING TEMPERATURE If you like to temporarily change your w...

Страница 18: ...programmed into the system D INVERTING DISPLAY The Selectron Plus display can be inverted to allow easier reading from inside the spa To do so first make sure TIME is displayed Use VIEW button to chan...

Страница 19: ...ver and allow the water temperature to cool down to 104 degrees F Then reset the system by holding down the PROG button for 5 seconds If the HILI message returns call for service K H E E T PUMP Each s...

Страница 20: ...60 Hz electricity In areas powered by 50 Hz the temperature will automatically be displayed in Celsius C on your display HEAT DAYS If your spa is located in a weekend home or if your schedule allows...

Страница 21: ...outer rim of the jet s clockwise for minimum pressure and counter clockwise for maximum pressure Pressure may also be varied by the use of the air control This jet can be removed for cleaning by turni...

Страница 22: ...rimary or secondary two speed pumps are operating Water may be diverted to two individual sections of jets or a combined operation of both sections Do not adjust when pump is set at high speed For the...

Страница 23: ...ed I WATERFALL OPERATIONS On the Nuage and Romance model spas This valve increases or decreases volume of water from the waterfall On the Nuage a second valve of this type increases or decreases the v...

Страница 24: ...o activate VitAroma insert one of Vita Spa s exclusive aromatherapy scents and turn on the VitAroma Induction System The system is activated when the light button is depressed a second time This syste...

Страница 25: ...ines shock with a chlorine or bromine shock EVERY 4 MONTHS Drain and refill spa Replace SPARKLE CLEAR cartridge AS NEEDED If water looks hazy shock treat with 1 teaspoon of dichlor per 250 gallons NOT...

Страница 26: ...will suppress the foam but will not remove the soap from the water Eventually the soap build up in the water will concentrate enough to leave an unclean feeling on the user s skin causing sudsing and...

Страница 27: ...er with a garden hose to rinse it and remove the debris Using a large sponge or soft cloth and a mild soap solution 1 teaspoon dish washing liquid with 2 gallons of water scrub lightly in circular mot...

Страница 28: ...ING DO NOT ATTEMPT TO TOUCH OR IMMEDIATELY REPLACE A LAMP THAT HAS BEEN OPERATIONAL THE LIGHT ASSEMBLY CAN BE VERY HOT AND COULD CAUSE BURNS 1 Turn off the power to the spa 2 Remove the front panel of...

Страница 29: ...cant 10 Reassemble the valve and restore the power to the spa 11 Check the Top Side display and adjust for time PRIMING THE PUMP Every so often after a spa is filled or refilled a pump is operating bu...

Страница 30: ...esirable A two part bromine system or granular chlorine Dichlor are also acceptable sanitizers pH CONTROL pH is a measure of acidity and alkalinity of the spa water The recommended pH for spa water is...

Страница 31: ...prevent calcium build up Calcium hardness 120 to 250 ppm Spray filter element to remove loose particles MONTHLY Four to six weeks Two to three months Inspect and clean the spa filter cartridge It is i...

Страница 32: ...its from staining the finish of your spa If your water is known to contain high concentrations of these metalsitmaybe necessary to add an additional quantity of Spa Metal Inhibitor 3 Use a 3 Way Spa W...

Страница 33: ...anitizer Check and adjust Chlorine level if Chlorine is used TOO ALKALINE SCALING ZONE COMFORT ZONE TOO ACIDIC CORROSIVE ZONE ADD pH DECREASER TO LOWER pH IDEAL ADD pH INCREASER TO RAISE pH 8 4 8 2 7...

Страница 34: ...issolves very slowly is highly concentrated and was designed for concrete or plaster swimming pools It will cause damage to your spa CHEMICAL SAFETY INSTRUCTIONS When using chemicals read labels caref...

Страница 35: ...ergent Overused or old water Excessive organics Body oils and dirt Inadequate filtration SOLUTIONS Clean filter with a filter cleaner or degreaser Shock the spa with POTASSIUM PEROXY MONOSULFATE Incre...

Страница 36: ...Y MONOSULFATE maintain sanitizer at recommended level Raise pH with PH UP Shock with POTASSIUM PEROXY MONOSULFATE Maintain recommended sanitizer residual at all times super chlorinate Allow chlorine b...

Страница 37: ...seconds Normal system operation for one minute each day at 10 AM and at 6 PM Remove filter and check for debris in filter and filter adapter If FLO remains check for closed gate valves or see priming...

Страница 38: ...ll Heater is on Flashing Temperature Adjustment Mode Still Economy Mode No timer Icon means Standard Mode Flashing Day and Time Adjustment Mode Still Heater adjustment is locked Flashing Panel lock Al...

Страница 39: ...__ _____________________________________________________ _____________________________________________________ _____________________________________________________ ___________________________________...

Страница 40: ...47th Street Miami Florida 33054 Phone 305 685 2063 or 305 908 8187 Toll Free 877 240 9457 FAX 305 685 9794 MIAMI FLORIDA Vita International Division of Is a Registered Trademark of SPA02 0228PDF 2002...

Отзывы: