CL E A RA NCES

CHECK THE FOLLOWING AREAS P RIOR TO SPA DELIVERY

1

. STEPS - We suggest no more than six without a landing. 

2

. TREE BRANCHES - Clearance for spa passage.

3

. TIGHT CORNERS - Make sure there is space to maneuver.

4

. STORAGE SHEDS, DOG HOUSES, WOOD PILES - Remove out of the way.

5

. GATES: CLEARANCE FOR PA S S AGE OF SPA - Does gate need to be removed

from hinges?

6

. OVERHANGS AND GUTTERS - Anything overhead, as well as drain pipe

locations, must allow for spa passage.

Содержание L100 SERIES

Страница 1: ...h e a l t h a n d r e l a x a t i o n f o r l i f e L100 SERIES OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Страница 2: ...PAGE 2 h e a l t h a n d r e l a x a t i o n f o r l i f e L100 SERIES OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Страница 3: ...___________________________________ TELEPHONE ___________________________________________ SERIAL ______________________________________________ MODEL _____________________________________________ To c...

Страница 4: ...Panel Lock 15 E Freeze Protection 15 F Flow Protection 16 G Overheat Protection 16 H Ozone Generator Monitor 16 Add Start Up Chemicals 16 Jet Operation 17 A Three Way PowerDiverter Valve 17 B Turbo M...

Страница 5: ...intenance We suggest that you take some time to carefully review it Please keep this manual available for reference If you have any questions regarding your Vita Spa set up operations or maintenance p...

Страница 6: ...ng with one rated less than the flow rate marked on the original suction fitting Install the spa so proper drainage is provided for the compartment containing electrical components DANGER RISK OF ELEC...

Страница 7: ...GFCI pro tected circuit This GFCI is required by the National Electrical Code NEC and must be installed by licensed electrician Test the GFCI monthly DO Test the water with your hand before entering t...

Страница 8: ...the spa 5 fetal damage in preg nant women and 6 unconsciousness resulting in a danger of drowning WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in...

Страница 9: ...may pose obstruc tions to deliver the spa to its intended site MAINTENANCE Trees lawn placement surfaces etc can create extra work in keeping your spa area clean and safe Please be advised that placi...

Страница 10: ...nding 2 TREE BRANCHES Clearance for spa passage 3 TIGHT CORNERS Make sure there is space to maneuver 4 STORAGE SHEDS DOG HOUSES WOOD PILES Remove out of the way 5 GATES CLEARANCE FOR PASSAGE OF SPA Do...

Страница 11: ...TO THE ROD SHOULD BE 6 BARE COPPER ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT THE INSTAL LATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN 10 VISUAL FEET FROM THE SPA AND NOT LES...

Страница 12: ...PAGE 8 COMMON NEUTRAL GROUND BAR IN MAIN SEPARATE NEUTRAL WEAK GROUND OR ROMEX WIRE USED TO FEED GFCI WITH UNDERSIZED GROUND WIRE...

Страница 13: ...PAGE 9 GFCI IN PANEL WITH SEPARATE NEUTRAL AND SOLID GROUND TO PANEL GFCI IN PANEL WITH COMMON NEUTRAL BAR AND OR ROMEX WITH UNDERSIZED WIRE USED TO FEED DISCONNECT...

Страница 14: ...10 GFCI MOUNTED IN PANEL AND DISCONNECT MOUNTED INSIDE TO COMMON WALL WITH METAL STUDS OR WITH METAL MOUNTING BOX GFCI IN PANEL WITH WEAK GROUND OR ROMEX WITH UNDERSIZED GROUND WIRE USED TO FEED DISCO...

Страница 15: ...s recommended The wire size for the distance of the wire run must conform to NEC and local electrical codes 5 To ensure proper connections use copper conductors only DO NOT USE ALUMINUM WIRE 6 The spa...

Страница 16: ...own straps Utilizing the cover anytime the spa is not in use will reduce heat loss and thereby reduce the amount of running time required to make up that loss by the heating sys tem Keep cover fastene...

Страница 17: ...d water OPERATING INSTRUCTIONS WATER LINE INITIAL START UP Your L100 Series spa has been factory programmed for your convenience Once properly connected the filtration pump and heater will automatical...

Страница 18: ...ome on during pro grammed hours See Setting Filtration Hours Note that if at the end of filtra tion cycle the water is not at the chosen temperature the pump and heater will not continue to run until...

Страница 19: ...s will turn on and run for at least one minute The display will show ICE After one minute if the water is still below 50 degrees F 10 degrees Celsius the heater will turn on and raise the water temper...

Страница 20: ...utton for 5 seconds while in time display mode If the HILI message returns call for service H OZONE GENERATOR MONITOR If your spa is equipped with a Vitazone ozone generator the ozone bulb is mon itor...

Страница 21: ...g the valve to the left water will be diverted to A jet s giving that zone the maximum output Rotating the valve to the right will give B jet s the maximum output When turned to the center both A and...

Страница 22: ...py The water pressure can be adjusted in both jets by rotating the outer rim of the jet clockwise for minimum pressure and counter clockwise for maximum pressure Water pressure can also be varied by o...

Страница 23: ...to increase open jet pressure or decrease close jet pressure as desired F CLUSTER JETS These jets work as a team that s why they re usually found in groups of two or more They can deliver vigorous pi...

Страница 24: ...ss the foam but will not remove the soap from the water Eventually the soap build up in the water will concentrate enough to leave an unclean feeling on the user s skin caus ing sudsing and make the w...

Страница 25: ...ub lightly in circular motion Then rinse it thoroughly with plenty of water Condition the vinyl after cleaning by applying a thin film of vinyl conditioner NOTE To remove tree saps use lighter fluid n...

Страница 26: ...eriod of time sand or grit may intrude into your spa The diverter valves may become difficult to turn It is important that the debris be removed as soon as possible to avoid damage to the valve 1 Turn...

Страница 27: ...troy bacteria and organic compounds in the spa water a sanitizer must be used regularly The use of ozone as an oxidizer has proven to be an effective method to help maintain water cleanliness but a re...

Страница 28: ...event calcium build up Calcium hardness 120 to 250 ppm Spray filter element to remove loose particles MONTHLY Four to six weeks Two to three months Inspect and clean the spa filter cartridge It is imp...

Страница 29: ...ded type of sanitizer Sodium dichlor dissolves easily and has a neutral pH which minimizes the effect that the addition of a sani tizer has on a pH balance Trichlor compounds are not recommended becau...

Страница 30: ...d 29 Please read WATER MAINTENANCE then follow these easy steps 1 Fill your spa until the water level is 1 inch above the highest jet It is NOT advisable to use softened water in your spa as may becom...

Страница 31: ...sanitizer Check and adjust Chlorine level if Chlorine is used BALANCING THE SPA WATER 3 DAY A WEEK SPA CARE PROGRAM Note The above table is an example only Actual spa usage will determine the amount o...

Страница 32: ...s solves very slowly is highly concentrated and was designed for concrete or plaster swimming pools It will cause damage to your spa CHEMICAL SAFETY INSTRUCTIONS When using chemicals read labels care...

Страница 33: ...wth Buildup of body oils lotion and chemicals resulting in soap or detergent Overused or old water Excessive organics SOLUTIONS Clean filter with a filter cleaner or degreaser Shock the spa with POTAS...

Страница 34: ...r with a filter cleaner or degreaser Shock with POTASSIUM PEROXY MONOSULFATE adjust pH Shock with POTASSIUM PEROXY MONOSULFATE maintain sanitizer at recommended level Raise pH with PH UP Shock with PO...

Страница 35: ...sible unlock by depressing the UP button for 5 seconds Normal system operation for one minute each day at 10 AM and at 6 PM Remove filter and check for debris in filter and filter adapter If FLO remai...

Страница 36: ...on Flashing Temperature Adjustment Mode Still Heater adjustment is locked Flashing Panel lock All buttons are deactivated Still Filter is On Flashing Filter adjustment Mode ICON MEANING LCD DISPLAY G...

Страница 37: ...VED DM Industries Ltd 2320 Northwest 147th Street Miami Florida 33054 Phone 305 685 2063 or 305 908 8187 Toll Free 877 240 9457 FAX 305 685 9794 MIAMI FLORIDA Vita International Division of Is a Regis...

Отзывы: