NTCS
April 2018
Visual Engineering
Video solutions. Integrated
visualengineering.co.uk
Page 8
Mesh Radio Configuration
Activating the Web Interface
The following web browser control interface is not required for normal operation.
Web browser control of the mesh radios should only be undertaken by users wishing to achieve the
following:
• Change the system frequency
• Change the system IP addresses
• Change the Encryption key
• Understand the RF performance of the system better
Users should be very careful when using this interface because it is entirely possible
to make changes that will leave the system inoperable, requiring the system to be
returned to base for repair.
Power up the an NTCS Camera Mesh node and make a direct network cable connection.
• Open a web browser on the PC
• Type the Node IP address of the Mesh node, e.g.
192.168.1.180
• The web browser opens the
Status Overview
page following a
Login Prompt
Type
192.168.1.180
here