Operating Manual of Inverted Microscope 

 

 

- 2 - 

  Safety Precautions & Reminder 

                                                                                                                                                                                                             

1. Be sure to turn off the power switch and remove the power cord plug before       
installing  this  unit,  replacing  the  bulb  /  fuse  or  plugging  and  unplugging  the 
power supply unit. This is to prevent electric shock or getting fingers burnt. 

                                                                                                                                                               

2.Check  unit  voltage  is  in  compliance  with  your  local  power  supply  voltage, 
otherwise  contact  your  supplier.  Improper  input  voltage  may  render  unit  not 
workable or a short circuit and damage the unit. 

                                                                                                                                                               

 

3.Use specified bulb, fuse and power cord which otherwise may damage the unit. 
Any extended power cord if used, must be grounded (PE). 

                                                                                                                                                         

 

4.  Do  not  expose  unit  to  high  temperatures  and  dampness.  Suitable  operating 
environment  is  between  5

°

C  to  35

°

C,  and  relative  humidity  of  20%-80%  (at 

25

°

C). Do not subject unit to direct sunlight.   

                                                                                                                                                                     

5.  Do  not  touch  the  halogen  lamp  box  when  using  the  unit  as  bulbs  inside 
generate  excess heat which can burn your  hand. Do not handle bulb with  bare 
hand 

within 

10 

minutes 

after 

switching 

off 

power                                               

supply as bulb is still hot, especially when changing a defective bulb. 

                                                                                                                                                             

6.  To  prevent  fire,  do  not  place  any  fibrous  product,  paper,  flammable  or 
explosive  material  (e.g.,  gasoline,  petroleum  ether,  alcohol)  near  the  halogen 
lamp box . 

                                                                                                                                                                                                                                                                                                                                   

7.When  using  coarse  /  fine  focus  knobs  or  height  adjustment  knob,  do  not 
continue  to  turn  them  beyond  the  limits  or  the  internal  mechanism  can  be 
damaged.. 

                                                                                                                                                                     

Warning! 

Warning! 

Warning! 

Warning! 

Warning! 

Warning! 

Warning! 

Содержание 82026-630

Страница 1: ...Inverted Microscope Model 82026 630 Operating Manual...

Страница 2: ...Our product has been design to provide the highest level of safety However improper operation or negligence in following the instructions in this manual may cause personal injuries and property losses...

Страница 3: ...nded PE 4 Do not expose unit to high temperatures and dampness Suitable operating environment is between 5 C to 35 C and relative humidity of 20 80 at 25 C Do not subject unit to direct sunlight 5 Do...

Страница 4: ...e 3 Table of Contents I Characteristics and applications 1 II Structural features 1 III Installation of this unit 2 IV Technical specifications 4 V Operation 5 VI Replacement of bulb and fuse 13 VII M...

Страница 5: ...the light path to perform transmitted phase contrast microscopic observation This unit is suitable for the microscopic observation of cells tissues and clear liquid tissues and the dynamic microscopi...

Страница 6: ...Operating Manual of Inverted Microscope 2 III Installation Caution Before installing be sure every components is clean no score any parts or glass surface 1 2 2 2 4 6 5 8 3 7 Fig 2...

Страница 7: ...condenser into the holder tighten the screw again As shown in Fig 3 3 Take out the stage bracket 2 when the stage bracket is used to carry a specimen or observe tissue in the culture dish put the des...

Страница 8: ...78 1 2 Objectives 40X 0 60 3 32 1 2 10X 0 25 8 80 1 2 Remark PHP2 25X 0 40 4 78 1 2 Remark PHP2 Phase contrast objective 40X 0 60 3 32 1 2 Remark PHP2 Ultra long working distance condenser Working di...

Страница 9: ...tment of the condenser height Before this unit is released from the factory the condenser already bears a calibrated height mark Turn the condenser height control knob to move the condenser into worki...

Страница 10: ...enter distance of the eyepiece tubes by turning the left or right frame body until the field of view becomes a fully overlapped circle as shown in Fig 8 b 6 Inspection of transmitted lighting path The...

Страница 11: ...enser center center of aperture diaphragm must be adjusted The center of the light spot can coincide with that of the field of view by adjusting two the centering screws of the condenser holder as sho...

Страница 12: ...be removed as shown in Fig 13 This cannot be done until the bulb is cool Wrap the bulb with a cotton fabric and adjust the bulb vertically gently in the direction indicated by the arrow in Fig 13 This...

Страница 13: ...gh the eyepiece Turn the coarse focusing control knob slowly to lower the objective When a specimen image appears in the field of view stop turning the coarse focusing control knob as shown in Fig 16...

Страница 14: ...fting mechanism is lowered Use a screwdriver to loosen the 3 mounting screws at the bottom of the stage moving device remove the stage moving device and lay it flatly on the worktable upside down Do n...

Страница 15: ...phase contrast objective into the light path and turn the phase contrast turntable or phase contrast puller to the 10 scale Turn condenser height control knob so that the phase contrast condenser rise...

Страница 16: ...dge clear 4 In the phase contrast observation mode the center of the dark ring should coincide with that of the bright ring If their centers do not coincide as shown in Fig 20 c it is necessary to cen...

Страница 17: ...b and its surroundings have cool down This is to prevent hand getting burnt by heat 3 Unscrew the screw loosen the screw and pull out the lamp holder from the halogen lamp housing Use a cloth to remov...

Страница 18: ...nless the electric components in this unit is still operating When this unit is not to be used for a long time remove the power plug from the supply socket and keep all cables properly 2 This unit sho...

Страница 19: ...a conforming halogen lamp Optical system and imaging The nosepiece has not been turned to the fixed position Turn the nosepiece to the fixed position The filament image deviates from the center of th...

Страница 20: ...not laid flatly Lay the specimen flatly on the object stage and hold it stably The phase contrast objective does not match the ring plate of the phase contrast condenser lens Align the phase contrast...

Отзывы: