VistaLab ali-Q 2000-0005 Скачать руководство пользователя страница 18

Declaration of Conformity 

VistaLab Technologies Inc. declares on its own responsibility that the devices

ali-Q aliquoting pipet controller, Model 2000-0005 

comply with:

Green/Ecodesign

 Regulations 

Meet CEC, DoE Level VI, Energy Star, ErP Stage 2

 

NRCan & GEMS

 

No Load Power Consumption Less 0.075W

 

Standards for EU 

Safety requirements for electrical equipment for measurement, control and 

laboratory use- General Requirements  

EN 61010-1:2010 

Electrical equipment for measurement, control and laboratory use- EMC 

requirements 

EN 61326-1:2013 

Standards for Canada and USA 

Safety requirements for electrical equipment for measurement, control and 

laboratory use- General Requirements  

CAN/CSA-C22.2 

No. 61010-1 

Safety requirements for electrical equipment for measurement, control and 

laboratory use- General Requirements 

UL 61010-1 

Operation is subject to the following two conditions: (1) this device may not 

cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation. 

Part 15 of the FCC 

Rules Class A 

<- Back to T.O.C

.

Copyright© 2017 VistaLab Technologies, Inc. USA. All rights reserved, including graphics and images. 

No part of this publication may be reproduced without prior permission of the copyright owner. 

VistaLab Technologies and the VistaLab Technologies logo are trademarks of VistaLab Technologies, Inc. USA. 

ali-Q is a trademark of VistaLab Technologies, Inc. 

Registered trademarks and protected trademarks are not marked in all cases with ® or ™ in this manual. 

U.S Patents are listed on www.vistalab.com/about/quality-management/

Lit # : L0

80-0060

-001 Rev 

C

         

P

 

a

 

g e

 | 

18

 

Information Technology Equipment Safety

 General Requirements

EN60950-1:2006

A2:2013

ali-Q 

LS 

aliquoting pipet controller, Model 2000-000

3

 

Содержание ali-Q 2000-0005

Страница 1: ...Operating Manual ali Q Aliquoting Pipet Controller Operating Manual or click here or scan QR code...

Страница 2: ...ode 7 Aliquot Mode 8 Intelligent Measuring System 9 LED Indicators 9 Technical Specifications 10 Troubleshooting 11 Maintenance 12 Cleaning Decontaminating 12 Autoclaving 12 Replacing Membrane Filter...

Страница 3: ...sories and spare parts See Ordering Information on pg 18 Do not attempt to make any technical alterations Do not dismantle the instrument any further than is described in the operating manual 9 Always...

Страница 4: ...harging port Micro USB N A 4 Aliquot button Nylon 5 Aspirate button Nylon 6 Dispense button Nylon 7 Battery Lithium ion Lithium Polymer 8 Battery compartment cover PC ABS 9 Nozzle Cover Nylon 10 Nozzl...

Страница 5: ...on verb To separate a volume of solution or suspension into aliquots Aspirate to fill with liquid Dispense to eject liquid Serological Pipet pipet disposable glass or plastic tube with volume graduati...

Страница 6: ...d control In Conventional Pipetting Mode see next page the speed that the ali Q aspirates and dispenses liquid is controlled by the touch sensitive aspirate and dispense buttons The amount of force us...

Страница 7: ...the bottom gray dispense button until bottom of meniscus is at the desired volume graduation ATTENTION Do not fill the pipet over the max volume Severe damage can occur if any liquid enters ali Q Dec...

Страница 8: ...d 4 Aliquot Carefully position the tip of the full pipet over the first receiving vessel Press and hold the purple aliquot button and the LED turns solid GREEN Hold button until green LED turns off an...

Страница 9: ...tions Temperature humidity and pressure all have significant effects on the performance of any liquid handling device EXCEPT for the ali Q ali Q can sense changes in ambient conditions and compensate...

Страница 10: ...ANY brand serological pipet Optimal performance when using VistaLab Wobble not serological pipets Not for use with Pasteur pipets Mains power supply Input Voltage 100 240 VAC Frequency 50 60 Hz Input...

Страница 11: ...Wobble not pipets will significantly decrease damage to the nozzle insert Out of Calibration Using different equipment different density liquid varying environmental conditions Membrane filter clogge...

Страница 12: ...ation lamps NOTE The effects of the UV exposure will likely cause discoloration over time Autoclaving NEVER AUTOCLAVE ALI Q Only the nozzle cover nozzle insert and membrane filter can be detached from...

Страница 13: ...cord into the charging port of the ali Q under the aliquot volume dial ali Q can s ll be used when plugged into charger Replacing the Ba ery Removing Battery Hard reset 1 Remove battery cover On the...

Страница 14: ...n at least once a year or whenever conditions and equipment change In lab Verification Adjustment Users can verify the accuracy of the dispensed aliquots in four ways 1 Gravimetric Use a digital scale...

Страница 15: ...used For warranty claims please contact Technical Support to receive Return Authorization Unit will be inspected for defects and repaired replaced as necessary at the sole discretion of VistaLab Cust...

Страница 16: ...zle Cover 1 pack 9020 9005 Replacement Power Supply w Universal outlet adapters 1 pack 9020 9008 Wall Mount 1 pack Wobble not Serological Pipets Catalog Number Description Quantity 4090 0005 Wobble no...

Страница 17: ...ervice life According to the Directive 2002 96 EC of the European parliament and of the Council on Waste Electrical Equipment WEEE of 27 January 2003 electronic equipment requires disposal according t...

Страница 18: ...General Requirements UL 61010 1 Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including...

Отзывы: