VistaLab ali-Q 2000-0005 Скачать руководство пользователя страница 15

P a g e

 | 

15

 

Warranty 

VistaLab guarantees the functionality of ali-Q for 

1 year

 from the Date of Manufacture (original proof of 

purchase required).  

VistaLab shall not be liable for the consequences of improper handling, use, servicing, operating or 
unauthorized repairs of the instrument or the consequences of normal wear and tear especially of wearing 
parts such as pistons, seals, valves and the breakage of glass as well as the failure to follow the 
instructions of the operating manual. We are not liable for damage resulting from any actions not 
described in the operating manual or if non-original spare parts or components have been used. 

For warranty claims, please contact Technical Support to receive Return Authorization. Unit will be 
inspected for defects and repaired/replaced as necessary at the sole discretion of VistaLab. Customer will 
be responsible for service charges for non-warranty damage.  

To validate warranty, register your ali-Q at 

www.vistalab.com/register-your-pipette

 

Send-in Service: 

To send your ali-Q sent in for routine calibration and maintenance or repairs, go to 

www.vistalab.com/service

 to create a service order and pre-pay using Purchase Order or Credit Card. 

Follow instructions on website and email confirmation to send-in for service. Be sure to decontaminate 
the unit before packaging. Put ali-Q into Shipping mode for safety by holding it completely upside-down 
and pressing purple aliquot button (red light will blink 2X). 

<- Back to T.O.C

.

Содержание ali-Q 2000-0005

Страница 1: ...Operating Manual ali Q Aliquoting Pipet Controller Operating Manual or click here or scan QR code...

Страница 2: ...ode 7 Aliquot Mode 8 Intelligent Measuring System 9 LED Indicators 9 Technical Specifications 10 Troubleshooting 11 Maintenance 12 Cleaning Decontaminating 12 Autoclaving 12 Replacing Membrane Filter...

Страница 3: ...sories and spare parts See Ordering Information on pg 18 Do not attempt to make any technical alterations Do not dismantle the instrument any further than is described in the operating manual 9 Always...

Страница 4: ...harging port Micro USB N A 4 Aliquot button Nylon 5 Aspirate button Nylon 6 Dispense button Nylon 7 Battery Lithium ion Lithium Polymer 8 Battery compartment cover PC ABS 9 Nozzle Cover Nylon 10 Nozzl...

Страница 5: ...on verb To separate a volume of solution or suspension into aliquots Aspirate to fill with liquid Dispense to eject liquid Serological Pipet pipet disposable glass or plastic tube with volume graduati...

Страница 6: ...d control In Conventional Pipetting Mode see next page the speed that the ali Q aspirates and dispenses liquid is controlled by the touch sensitive aspirate and dispense buttons The amount of force us...

Страница 7: ...the bottom gray dispense button until bottom of meniscus is at the desired volume graduation ATTENTION Do not fill the pipet over the max volume Severe damage can occur if any liquid enters ali Q Dec...

Страница 8: ...d 4 Aliquot Carefully position the tip of the full pipet over the first receiving vessel Press and hold the purple aliquot button and the LED turns solid GREEN Hold button until green LED turns off an...

Страница 9: ...tions Temperature humidity and pressure all have significant effects on the performance of any liquid handling device EXCEPT for the ali Q ali Q can sense changes in ambient conditions and compensate...

Страница 10: ...ANY brand serological pipet Optimal performance when using VistaLab Wobble not serological pipets Not for use with Pasteur pipets Mains power supply Input Voltage 100 240 VAC Frequency 50 60 Hz Input...

Страница 11: ...Wobble not pipets will significantly decrease damage to the nozzle insert Out of Calibration Using different equipment different density liquid varying environmental conditions Membrane filter clogge...

Страница 12: ...ation lamps NOTE The effects of the UV exposure will likely cause discoloration over time Autoclaving NEVER AUTOCLAVE ALI Q Only the nozzle cover nozzle insert and membrane filter can be detached from...

Страница 13: ...cord into the charging port of the ali Q under the aliquot volume dial ali Q can s ll be used when plugged into charger Replacing the Ba ery Removing Battery Hard reset 1 Remove battery cover On the...

Страница 14: ...n at least once a year or whenever conditions and equipment change In lab Verification Adjustment Users can verify the accuracy of the dispensed aliquots in four ways 1 Gravimetric Use a digital scale...

Страница 15: ...used For warranty claims please contact Technical Support to receive Return Authorization Unit will be inspected for defects and repaired replaced as necessary at the sole discretion of VistaLab Cust...

Страница 16: ...zle Cover 1 pack 9020 9005 Replacement Power Supply w Universal outlet adapters 1 pack 9020 9008 Wall Mount 1 pack Wobble not Serological Pipets Catalog Number Description Quantity 4090 0005 Wobble no...

Страница 17: ...ervice life According to the Directive 2002 96 EC of the European parliament and of the Council on Waste Electrical Equipment WEEE of 27 January 2003 electronic equipment requires disposal according t...

Страница 18: ...General Requirements UL 61010 1 Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including...