Barcode reader VB34
Installation
Da
te
of
issue
06/
1
3
/2005
22
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: G49 621 776-0 • USA +1 330 4253555 • Sin65 67799091 • Internet http://www.pepperl-fuchs.com
The following table shows the assignment of the connectors on the terminal block of
the C-BOX 100. Use this connection layout if the VB34 reader is connected to a net-
work via the C-BOX 100:
Connectors on the terminal block of the C-BOX 100
Power supply
1, 3, 5
VS
2, 4, 6
GND
7, 8
Grounding
20, 40
Reserved
Inputs
27
EXT TRIG A (polarity exchangeable)
28
EXT TRIG B (polarity exchangeable)
29
IN 2A (polarity exchangeable)
30
IN 2B (polarity exchangeable)
31, 33
IN 3A (polarity exchangeable)
32, 34
IN 4A (polarity exchangeable)
36
IN 3B/IN 4B reference earth (polarity exchangeable)
Outputs
21
Out 1+
22
Out 1-
23
Out 2+
24
Out 2-
25
Out 3A (polarity exchangeable)
26
Out 3B (polarity exchangeable)
Secondary interface
35
TX AUX
37
RX AUX
38, 39
GND
Primary interface
RS232
RS485
full duplex
RS485
half duplex
20 mA
(only INT-60)
11, 15
TX232
TX485+
CLOUT+
12, 16
RTS232
TX485-
RTX485-
CLOUT-
17
RX232
RX485+
CLIN+
18
CTS232
RX485-
CLIN-
10, 14,
19
SGND
Signal ground
SGND
Signal ground
SGND
Signal ground
9, 13
RS485
Shielding
RS485
Shielding