UltraReceiver User Manual
Safety and Compliance
Issue No: 3
Page: 1
Ref: ULRX-ASUM-700X
Copyright © 2018 Vislink plc
WARNING: Any mains power equipment must be earthed.
CAUTION: Connection and disconnection from the Mains supply is achieved through a
detachable mains cord. This must be of a suitable rating and cross-sectional
area, as well as being approved to the relevant national standards. The cord or
its plug must be easily accessible to allow it to be quickly disconnected.
CAUTION: Replacement fuses must be of identical ratings to the original parts fitted, i.e.
T5A H250
CAUTION: Operate the equipment within environmental limits and ensure as much
ventilation as possible (normally Temp 0°C - 50°C <99% humidity).
CAUTION: Only authorized personnel should open the product and any repair or warranty
will be invalidated if the seals are broken.
The equipment has been designed to be CE compliant and Technical files are available on
request.
To ensure awareness of potential hazards, all personnel concerned with the operation or
maintenance of the equipment must study the information that follows, together with
local site regulations.
WARNING: RF Power Hazard: High levels of RF power are present in the unit. Exposure to
RF or microwave power can cause burns and may be harmful to health. Switch
off supplies before removing covers or disconnecting any RF cables, and before
inspecting damaged cables or antennas.
WARNING: Avoid standing in front of high gain antennas (such as a dish) and never look
into the open end of a waveguide or cable where RF power may be present.
CAUTION: Users are strongly recommended to return any equipment that requires RF
servicing to Vislink.
WARNING- GaAs / BeO Hazard: Certain components inside the equipment contain Gallium
Arsenide and Beryllium Oxide that are toxic substances. Whilst safe to handle
under normal circumstances, individual components must not be cut, broken
apart, incinerated or chemically processed. In the case of Beryllium Oxide, a
white ceramic material, the principal hazard is from the dust or fumes, which
are carcinogenic if ingested, inhaled or entering damaged skin.
Please consult your local authority before disposing of these components.
CAUTION: Tantalum Capacitors: When subjected to reverse or excess forward voltage,
ripple current or temperature these components may rupture and could
potentially cause personal injury.
CAUTION: This system contains MOS devices. Electro-Static Discharge (ESD) precautions
should be employed to prevent accidental damage.
SERVICE PERSONNEL - CAUTION DOUBLE
POLE/NEUTRAL FUSING