Antenna
Gain
(dBi)
Minimum Safe
Distance from
Antenna (cm)
Minimum Safe
Distance from
Antenna (inch)
0
13
5.12
29
356
140.12
36
797
313.70
40
1262
496.72
43
1783
701.79
P
o
w
e
r
D
e
n
s
it
y
(
m
W
/c
m
^2
)
High Power
MaximumPermissible Exposure
All Bands, High Power 33dBm)
80
70
60
50
40
30
20
10
0
0 2 4 6 8 10121416182022242628303234363840424446485052545658
DistanceinFeet
0dBi
29dBi
36dBi
40dBi
43dBi
2.2.3 Grounding the DXL8000
CAUTION
Be sure the equipment grounding follows applicable electrical codes.
Never modify a grounded power plug to connect to an ungrounded
receptacle.
For safe operation, all equipment must be properly grounded.
• Make the ground wire as short and straight as possible.
• Connect the DXL8000 IDU ground lug to the common ground on the installation.
• Connect the common ground to site ground.
2.2.4 Ventilating the DXL8000
CAUTION
Temperatures inside a closed mounting area can be significantly higher
than the ambient temperature. Always allow adequate ventilation.
If possible, install components in a climate-controlled area. Allow adequate airflow around the
equipment. Exhaust air from the rack should be circulated and not trapped in a closed space.
2.2.5 Protecting the DXL8000 from Moisture
Locate the equipment in an area protected from dripping water or excessive humidity.
WARNING
If water penetrates the chassis, it could cause equipment damage and
create a safety hazard.
2-4 Installing the DXL8000
DXL8000 User and Technical Manual
Содержание DXL8000
Страница 45: ......