Advent Communications
209297 – DCU5000 Drive Control Unit
Page 33 of 42
Calibration
Command:
QUC
Response:
UC
abcde
a
Azimuth calibration
C : Calibrated.
U : Uncalibrated.
b Elevation
calibration
c Polarization
calibration
d
Axis 4 calibration
e
Axis 5 calibration
Limit States
Command:
QUL
Response:
UL
ABCDE
A
Azimuth
limits
B
Elevation
limits
C
Polarisation
limits
D
Axis 4 limits
E
Axis 5 limits
Limit coding
a : OK.
b
:
Clockwise
softlimit.
c
:
Anti-Clockwise
softlimit.
d
:
Clockwise
freewheel.
e
:
Anti-Clockwise
freewheel.
f
:
Clockwise
travel
limit.
g
:
Anti-Clockwise
travel
limit.
h
:
Clockwise
Stall.
I
:
Anti-Clockwise
Stall.
Waveguide Switch Position
Command:
QUW
Response:
UW
x
x
A : Position A.
B : Position B.
M : Moving
E : Error
Содержание ADVENT DCU5000
Страница 3: ...Advent Communications EMC DECLARATION 209297 DCU5000 Drive Control Unit Page 3 of 42 ...
Страница 41: ...Advent Communications 209297 DCU5000 Drive Control Unit Page 41 of 42 8 FIGURES ...