4.39. F39: FAN POWER SUPPLY ALARM
The internal heatsink fan power supply is out of specification.
4.40. F40: BRAKE POWER SUPPLY ALARM
The brake power supply is out of specification. Either the supply has been shorted on
the antenna, or an internal DCU5000 supply rail has failed.
4.41. F41: FEED POWER SUPPLY ALARM
The DCU5000 does not have a feed power rail. This alarm should never be triggered, if
seen please report the occurrence to Advent Communications customer support.
4.42. F42: GPS/COMPASS POWER SUPPLY ALARM
The GPS/Compass power supply is out of specification. Either the supply has been
shorted on the antenna, or an internal DCU5000 supply rail has failed.
4.43. F43: STATUS POWER SUPPLY ALARM
The DCU5000 does not have a status power rail. This alarm should never be triggered,
if seen please report the occurrence to Advent Communications customer support.
4.44. F44: AZ BRAKE DISCONNECTED
The DCU5000 is expecting a brake to be fitted on the azimuth axis. The brake has not
been detected on power-up.
4.45. F45: EL BRAKE DISCONNECTED
The DCU5000 is expecting a brake to be fitted on the elevation axis. The brake has not
been detected on power-up.
4.46. F46: POL BRAKE DISCONNECTED
The DCU5000 is expecting a brake to be fitted on the polarisation axis. The brake has
not been detected on power-up.
4.47. F47: AXIS 4 BRAKE DISCONECTED
The DCU5000 does not have an axis 4 drive. This alarm should never be triggered, if
seen please report the occurrence to Advent Communications customer support.
4.48. F48: AXIS 5 BRAKE DISCONNECTED
The DCU5000 does not have an axis 5 drive. This alarm should never be triggered, if
seen please report the occurrence to Advent Communications customer support.
4.49. F49: MAIN UNIT FAN SERVICE
The main unit fan run time has exceeded the service time programmed. Consider
replacing the DCU5000 main cooling fan, contact Advent Communications customer
support for further information.
4.50. F50: HEATSINK FAN SERVICE
The heatsink fan run time has exceeded the service time programmed. Consider
replacing the DCU5000 heatsink cooling fan, contact Advent Communications
customer support for further information.
4.51. F51:
E
2
PROM CHECKSUM ERROR
A checksum error has been detected in a page of the E
2
PROM memory area.
4.52. F52: SOFTLIMIT DATA ERROR
An error has been detected whilst reading the units softlimit settings. The values have
been set to their default values. If the antenna system requires restricted antenna
movement, check values and confirm the safe operation of the antenna system.