27
Analysis
Criteria
Settings
Acceleration/Brake
This sets the criteria for excessive acceleration and brake. This is measured in G‐
force, so if acceleration or deceleration exceeds the G‐force limit, it will be
counted as excessive.
Speed
Limit
This option allows you to set the criteria for excessive speeding. You can set the
value limits between 0‐999km/h. In the example above, the limit has been set to
80km/h for 30 seconds, so therefore if the vehicle goes over this speed for over
30 seconds, it will count as excessive speeding. If you go over that speed but for
under 30 seconds, it will not count as excessive speeding.
Eco
‐
speed
Limit
Set the criteria for eco‐speed limit. The eco‐speed limit can be set higher or lower
than the speed limit and can be set from 0‐999 km/h and the time can be set by
selecting the drop down menu. In the example, the limit has been set to 60km/h
for 10 seconds. If this limit is exceeded, it will count as excessive.
Analysis
Criteria
Settings
This option allows you to make changes to the analysis criteria settings. To
access this menu, go to ‘settings’ click ‘analysis criteria settings’ and you will
be presented with the following screen.
28
Grading Criteria Settings
The criteria for grading driver’s safety and eco‐score can be set in these settings.
The safety and eco‐grading criteria have 7 and 8 separate components
respectively. A weighted average of these component scored are used to
determine an overall score.
Grading for each criteria is set to 4 levels (A,B,C & D) and if the driver’s score is
lower then they will receive an F for fail. Each criteria can be given a different
weight depending on the importance you place on each one but all weights must
add up to 100. To get into this menu, enter the ‘Settings’ menu, and click the
‘Grading Criteria Settings’.
Sudden
Start
Count
This option sets the grading criteria the amount of sudden starts per hour. The
assessment of this criteria is based on the (acceleration/deceleration). For
example, if a driver drove for 8 hours in one day and had 4 sudden starts during
that time, their score for that criteria will be 0.5 and based on the settings in the
image above, they would be graded as B.
This criteria is used in both safety and eco grading, but the weights can be set
separately.
27
28
GRADING CRITERIA SETTINGS
ANALYSIS CRITERIA SETTINGS
Содержание VT1000
Страница 20: ......
Страница 21: ...http www visiontrack com ...