background image

 

Chapter 1. Product Description

 

 

1.1 Overview 

VS-AXESS-4DLX is a powerful and stable access controller, using the logical architecture design. 

VS-AXESS-4DLX is designed with TCP/IP  network interface and its signal processed with special 
encryption and can be run offline. Anti-tampering function is also supported. 
 

1.2 Product Function 

 

The access controller is equipped with 32-bit high-speed processor; 

 

Supports  TCP/IP  network  communication,  with  self-adaptive  network  interface.  The 
communication data is specially encrypted to relieve the concern of privacy leak; 

 

Support recognition and storage of card number with maximum length of 20; 

 

The access controller can store 100 thousand legal cards and 300 thousand card swiping 
records; 

 

Supports multi-door interlock function, anti-passback function, multi-card function, first card 
open function, super card and super password function, online upgrade function and remote 
control of the doors; 

 

Supports tamper-proof alarm for card reader, alarm for door not secured, force opening door 
alarm, alarm for door opening timeout, duress card and code alarm, blacklist alarm and alarm 
for illegal card swiping attempts reaching the limit.; 

 

The alarm input of controller supports short circuit protection function and cut-proof function; 

 

Supports RS485 interface and Wiegand interface for accessing card reader. RS485 interface 
adopts  dual-interface  design  and  supports  loop  breakpoint  detection  and  redundancy 
function; Wiegand interface supports W26, W34 and is seamlessly compatible with third-party 
card reader with Wiegand interface; 

 

Supports various card types as normal/ disabled/ blacklist/ patrol/ guest/ duress/super card, 
etc.; 

 

Various indicators to show different status; 

 

Supports time synchronization via NTP, manual or automatic method; 

 

Supports  record  storage  function  when  it  is  offline  and  insufficient  storage  space  storage 
alarm function; 

 

The  access  controller  has  backup  battery  design,  watchdog  design  and  tamper-proof 
function; 

 

Data can be permanently saved after the access controller is powered off. 

 

Supports I/O linkage, and event linkage; 

 

Supports Ehome protocol, and inter-network communication. 

 

500 groups of password under the authentication mode of card and password; 

 

 
 
 
 
 
 
 

Содержание VS-AXESS-2DLX

Страница 1: ...1 Two Door Access Controller Panel Board TCP IP Wiegand with Software and Power Supply Included 100 000 Users VS AXESS 4DLX Installation Manual...

Страница 2: ...r TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS WITH ALL FAULTS AND ERRORS AND VISIONIS MAKES NO WARRANTIES EXPRESS...

Страница 3: ...undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards liste...

Страница 4: ...ow these precautions to prevent potential injury or material damage Tips The additional information as a complimentary of the contents Warnings Please adopt the power adapter from the legitimate facto...

Страница 5: ...ion of Cathode Lock 15 4 3 2 Installation of Anode Lock 15 4 4 CONNECTING THE EXTERNAL ALARM DEVICE 16 4 5 DOOR BUTTON WIRING DIAGRAM 16 4 6 THE CONNECTION OF MAGNETICS DETECTION 17 4 7 CONNECTING POW...

Страница 6: ...ed force opening door alarm alarm for door opening timeout duress card and code alarm blacklist alarm and alarm for illegal card swiping attempts reaching the limit The alarm input of controller suppo...

Страница 7: ...ppearance 2 1 Component Description Access Controller Component Schematic Diagram Take VS AXESS 4DLX as an example the component schematic diagram is shown below Figure 2 VS AXESS 4DLX Component Schem...

Страница 8: ...NO 2 Network Data Indicator 3 RS 485 Communication Indicator 4 Network Status Indicator 5 Door Relay Output Status NC NO Choice 6 Battery Charging Indicator 7 Power Indicator 8 Charging Completing Ind...

Страница 9: ...9 Chapter 3 Terminal Connection 3 1 Terminals Description Figure 3 1 VS AXESS 4DLX Terminal Description...

Страница 10: ...eader Control Output A15 ERR Cresset of Card Reader Control Output Invalid Card Output A16 OK Cresset of Card Reader Control Output Valid Card Output A17 Wiegand Card Reader 2 GND Grounding A18 W0 Wie...

Страница 11: ...ng B17 S2 Door 2 Magnetic Detector Input B18 S3 Door 3 Magnetic Detector Input B19 GND Signal Grounding B20 S4 Door 4 Magnetic Detector Input B21 Door Button B1 Door 1 Door Button Input B22 GND Signal...

Страница 12: ...arm Input 2 D11 GND Grounding D12 C1 Event Alarm Input 1 Note The Alarm input hardware interface is normally open by default So only the normally open signal is allowed It can be linked to the buzzer...

Страница 13: ...tallation 4 2 1 The Connection of Wiegand Card Reader Figure 4 2 Wiring diagram of Wiegand card reader Note You must connect the OK ERR BZ if using access controller to control the LED and buzzer of t...

Страница 14: ...14 4 2 2 RS485 Card Reader Connection Figure 4 3 Wiring diagram of RS485...

Страница 15: ...15 4 3 Installing E Lock 4 3 1 Installation of Cathode Lock Figure 4 4 Wiring diagram of cathode lock 4 3 2 Installation of Anode Lock Figure 4 5 Wiring diagram of anode lock...

Страница 16: ...16 4 4 Connecting the External Alarm Device Figure 4 6 External Alarm Device Connection 4 5 Door Button Wiring Diagram Figure 4 7 Power Button Connection...

Страница 17: ...17 4 6 The Connection of Magnetics Detection Figure 4 8 Magnetics Connection 4 7 Connecting Power Supply Figure 4 9 Power Supply Connection...

Страница 18: ...18 4 8 Arming Region Input Terminal 4 8 1 Connecting Normally Open Detector Figure 4 10 Normally Open Status 4 8 2 Connecting Normally Closed Detector Figure 4 14 Normally Closed Status...

Страница 19: ...ning 3 After the buzzer stops jump the jumper cap back to Normal 4 Disconnect the power and restart the access controller Figure 5 1 Initialization Dial up Note The initializing of the hardware will r...

Страница 20: ...losed Status Figure 5 3 Normally Closed Status 5 2 2 Alarm Relay Output Status Alarm Relay Output Normally Open Figure 5 4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5...

Страница 21: ...21 Work Flow of Software For detailed information please see the user manual of the client software Refer to the following work flow Figure 6 1 Software Client Work Flow...

Страница 22: ...r detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the official website and install the SADP according to the prompts Follow...

Страница 23: ...heckbox of Enable DHCP 6 Input the password and click the Save button to activate your IP address modification STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own...

Страница 24: ...l the software according to the prompts Follow the steps to activate the control panel Steps 1 Run the client software and the control panel of the software pops up as shown in the figure below 2 Clic...

Страница 25: ...ton to start activation STRONG PASSWORD RECOMMENDED We highly recommend you create a strong password of your own choosing using a minimum of 8 characters including upper case letters lower case letter...

Страница 26: ...ity 16M Uplink Communication Interface TCP IP Interface and RS 485 Interface Downlink Communication Interface RS 485 and Wiegand Normal Card Event Log 100 000 normal card and 300 000 card wiping logs...

Отзывы: