background image

Testing Mode: Test the alarm weekly by pushing the test switch for about 3 sec. until there are 3 beeps and 

red LED light on continuously. Then, the smoke detector will send an alarm report (type: smoke alarm, state: 

alarm) to the user’s controller and also the dectecor will send an alarm report (type: smoke alarm, state: No 

alarm). Please note if the detector only beep once and red LED flashes three times, it indicates the detector 

is not working properly. Please require to repair or service.

Battery Power indicator: The detector will report the current status of battery capacity to the user’s 

controller.

Self-Protection Mode: If the detector is removed from bracket, the detector will send an alarm (type:smoke 

alarm, level:0xFF) to the Z-Wave Interface Controller, and the yellow LED will flash continuously and the 

detector will sound.

Silence Mode: The user could press the test switch to get into silence mode to turn off the alarm 

temporarily. The silence function will automatically turn into normal operation after 10 minutes if the smoke 

concentration around the detector is still at alarming level.

Wakeup Intervals - how to communicate with the device?

W

 This device is battery operated and turned into deep sleep state most of the time to save battery 

life time. Communication with the device is limited. In order to communicate with the device, a static 

controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices 

and store commands that can not be received during deep sleep state. Without such a controller, 

communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup 

Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with 

the desired wakeup interval and the node ID of the controller. If the device was included by a static 

controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff 

between maximal battery life time and the desired responses of the device.

Hitting the programm button will wake up the device.

It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to 

go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup.

Node Information Frame

NI

 The Node Information Frame is the business card of a Z-Wave device. It contains information 

about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed 

by sending out a Node Information Frame. Beside this it may be needed for certain network operations to 

send out a Node Information Frame.

Hitting the programm button will send out an Node Information Frame.

Associations

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4 

Содержание VIS_ZS6101

Страница 1: ...communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referr...

Страница 2: ...e smoke sensitivity is 0 5 ft 4 ft The smoke detector has a test button and a flashing LED so you always know that the smoke alarm is working correctly The smoke alarm will warn you when the battery is low When the device detects smoke it will give a loud warning sound It will also trigger actions in other Z Wave devices or Z Wave controllers to escalate the alarm The Smoke Detector can also activ...

Страница 3: ...usion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Exclusion and Inclu...

Страница 4: ...th the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a...

Страница 5: ...vent happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 alarm messages max nodes in group 5 Command Classes Supported Command Classes Battery version 1 Basic version 1 Wake Up version 2 Association version 1 Version version 1 Alarm version 2 Manufacturer Specific version 1 Alarm Sensor version 1 Technical Data Battery Type 3 C...

Страница 6: ...ssociation is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product contains batteries Please remove the ...

Отзывы: