Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate 

plastic anchor and screw. Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic 

anchor, and attached the bracket by using the screws.

Open the battery cover to insert the batteries, and then replace the cover. Fix the detector with bracket by 

rotating it clockwise.

Please follow the recommendations about amount as position of the sensor in your home as given above. 

Avoid to place the sensor into the angle of walls, prefer positions in the middle of the room.

Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an 

existing wireless network to communicate with the devices of this network. This process is called Inclusion

Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the 

primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion 

mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or 

exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave 

the network. Leaving the network - i.e. being excluded - sets the device back to factory default.

If the device already belongs to a network, follow the exclusion process before including it in your network. 

Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to 

be reset first.

Exclusion and Inclusion is confirmed by hitting the programm button.

Operating the device

Power-on Mode: 1) Install the battery into the module 2) Close the bracket

3) the detector will take 8 to 12 sec. and emit a beep to confirm and start the burglar system. The detector 

will alarm once remove the bracket. 

Stand-by Mode: The red LED flashes one time every 11 seconds.

Alarm Mode (It is the status when the alarm is triggered.): If a certain density of smoke is detected, an 

audible alarm with 3 beeps, break and 3 beeps will occure. The red LED will flash continuously and rapidly. 

Meanwhile, the smoke detector will send an alarm report (type: smoke alarm, state: alarm) to the user’s 

controller and also the detector will send an alarm report (type: smoke alarm, state: No alarm).

Error Mode: If the smoke detector beeps and yellow LED flashes three times, it indicates the smoke 

detector is not working properly. Please require to repair or service.

Low battery warning Mode: The yellow LED will flash once every 43 seconds with a short “beep” sound.

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 3 

Содержание VIS_ZS6101

Страница 1: ...communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referr...

Страница 2: ...e smoke sensitivity is 0 5 ft 4 ft The smoke detector has a test button and a flashing LED so you always know that the smoke alarm is working correctly The smoke alarm will warn you when the battery is low When the device detects smoke it will give a loud warning sound It will also trigger actions in other Z Wave devices or Z Wave controllers to escalate the alarm The Smoke Detector can also activ...

Страница 3: ...usion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Exclusion and Inclu...

Страница 4: ...th the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a...

Страница 5: ...vent happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 alarm messages max nodes in group 5 Command Classes Supported Command Classes Battery version 1 Basic version 1 Wake Up version 2 Association version 1 Version version 1 Alarm version 2 Manufacturer Specific version 1 Alarm Sensor version 1 Technical Data Battery Type 3 C...

Страница 6: ...ssociation is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product contains batteries Please remove the ...

Отзывы: