background image

A

 Z-Wave devices control other Z-Wave devices. The relationship between one device 

controlling another device is called association. In order to control a different device, the controlling device 

needs to maintain a list of devices that will receive controlling commands. These lists are called 

association groups  and they are always related to certain events (e.g. button pressed, sensor triggers, ...). 

In case the event happens all devices stored in the respective association group will receive a common 

wireless command.

Association Groups:

1 alarm messages (max. nodes in group: 5)

Command Classes

Supported Command Classes

Battery (version 1)

Basic (version 1)

Wake Up (version 2)

Association (version 1)

Version (version 1)

Alarm (version 2)

Manufacturer Specific (version 1)

Alarm Sensor (version 1)

Technical Data

Battery Type

3 * CR123A

Explorer Frame Support Yes

SDK

4.54.00

Device Type

Slave with routing capabilities

Generic Device Class

Alarm Sensor

Specific Device Class

Routing Smoke Sensor

Routing

No

FLiRS

No

Firmware Version

3.5

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Содержание VIS_ZS6101

Страница 1: ...communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referr...

Страница 2: ...e smoke sensitivity is 0 5 ft 4 ft The smoke detector has a test button and a flashing LED so you always know that the smoke alarm is working correctly The smoke alarm will warn you when the battery is low When the device detects smoke it will give a loud warning sound It will also trigger actions in other Z Wave devices or Z Wave controllers to escalate the alarm The Smoke Detector can also activ...

Страница 3: ...usion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Exclusion and Inclu...

Страница 4: ...th the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a...

Страница 5: ...vent happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 alarm messages max nodes in group 5 Command Classes Supported Command Classes Battery version 1 Basic version 1 Wake Up version 2 Association version 1 Version version 1 Alarm version 2 Manufacturer Specific version 1 Alarm Sensor version 1 Technical Data Battery Type 3 C...

Страница 6: ...ssociation is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product contains batteries Please remove the ...

Отзывы: