VC_nano_Series.pdf – VC nano Series Smart Cameras Operating manual
1996-2014 Vision Components GmbH Ettlingen, Germany
30
The trigger output can be set to exposure controlled mode – for instance to control a light source. With
TRIGOUT_EXP() combined with TRIGOUT_POS(), the trigger output is high during exposure.
TRIGOUT_EXP() combined with TRIGOUT_NEG(), the trigger output is low during exposure.
Trigger Output Signal in Exposure Controlled
Mode:
TRIGOUT_EXP();
AND
Trigger output set positive:
TRIGOUT_POS();
The trigger macros are also described in our programming tutorial.
For VC6xxx nano cameras, the macros TRIGOUT_USR(), SET_TRIGOUT() and RES_TRIGOUT()
(manual trigger output control) are only available from board version 1.2 (version is written on
the board, above the sensor)! For VC6210 camera from S/N 7100068 and for VC6211 camera
from S/N 7700029.
t
V
Trigger Output
!