3.2.3.2
Connection of PLC/trigger outputs VC nano Series
relais,
motor,
etc.
GND
(black cable)
12-24V
(red cable)
inside camera
12-24V
+
-
4 digital outputs
-
1 trigger output
-
Operating Voltage 12 to 24 V
-
current per output: 400 mA (total
current all outputs < 1000 mA)
-
Connect 12-24 V PLC and camera
power supply pins 1, 2 and 9.
-
bit = 1 output will switch positive
voltage
-
short-circuit and over- temperature
protection (2A)
3.2.4
Available Accessories / Cables for Power Supply and IO Interface