9 Network Settings Recovery
When network settings are changed, the IP address, Net Mask and Gateway are validated before they are
saved. However if the settings are such that the Predator-HD has settings which mean that it cannot be seen
on the user’s network, it may become necessary to use the ‘Network Settings Recovery’ feature as described
below.
The ‘Network Settings Recovery’ IP address may conflict with an IP address that is already defined on the
network, it may be necessary to disconnect the Predator-HD from the network and control it locally using a
network connection to a laptop so that the IP address can be set to a suitable setting before the Predator-HD is
reconnected to the main network.
Procedure for ‘Network Settings Recovery’
If necessary disconnect the Predator-HD from the main network.
Turn power to the Predator-HD OFF for 3 seconds.
Turn power to the Predator-HD ON for 4 seconds.
Repeat the above five times.
On the final power ON, leave the power switched on for at least 5 minutes to allow the Predator-HD to initialise.
(See section Locating the Predator-HD on your network - page 18).
10 Special Presets
Illumination
(when it is dark)
Seek 64
(On)
IR
(mono/colour not changed)
Seek 66
(Off)
Seek 65
(On)
White Lights
(mono/colour not changed, no timer)
Seek 66
(Off)
Night Sensor
(when it is dark)
Seek 67
(Mono)
Seek 68
(Colour)
Night Focus Range
(when it is dark)
Seek 69
(Ambient)
Seek 70
(IR)
Wiper
Seek 81
Double Wipe
Seek 86
(Stop)
Seek 82
Permanent Intermittent Wipe
Seek 83
Permanent Fast Wipe
Seek 84
Timed Intermittent Wipe
Seek 85
Timed Fast Wipe
De-Fog
Seek 87
(On)
Seek 88
(Off)
Washer
Seek 89
(Start)
Define Preset 359
(Defines Washer Position)
Seek 90
(Stop)
White Lights
(when it is dark)
Seek 100
(On)
White Lights
change to colour, timer is used)
Seek 101
(Off)
Thermal Camera
(if fitted)
Seek 102
Digital Zoom Off
Seek 103
Digital Zoom x2
Seek 104
Digital Zoom x4
Seek 105
Display Blue Spot, read Spot Temperature
Seek 106
Remove Spot Temperature
Seek 107
Turn off all Thermal alarms
Seek 108
Do FFC (Flat Field Correction)
Power on Park
Define/Seek 150
Program/Recall Power on Park preset position.
White Light Exclusion
Define 151
Set Left Side
Define 152
Set Right Side
Home
Define 360
Defines Home Position