Predator-HD Installation Manual V2.1.21.03
Page 17
© 360 Vision Technology Ltd.
Please make sure there is adequate spare cable (20cm) for when the camera is resting on the lanyard, failure
to do this could damage the connector circuit board.
• Open the hinge taking care that the gasket is not damaged and support the weight of the Predator.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support the
weight of the Predator, there is no need to continue to support the Predator. The connection circuit
board (PCB-000-0222-02) can now be seen.
Thermal Camera (If camera is present)
Use BNC 1 if thermal camera is fitted to Predator.
Power Connections
Connect 24Vac to CON5.
Ethernet Connections
Connect Ethernet cable to HD HMA Predator connection
board using a RJ45 connector (CON4).
Alarm Connection (If feature is present)
Use CON6 to connect alarm signal to Predator PSU (PCB-
000-0240-xx) CON 2 (Video).
Washer Connection (If feature is present)
Use CON6 to connect washer signal to Predator washer
PSU (PCB-000-0240-xx) CON 9
Audio Connection (If feature is present)
Use CON7 to connect audio signal from/to the Predator.
Line In
Speaker with Impedance of 8 OHM, 6W
Line Out
Single-Output 0.9V RMS, Line Output can drive a 10k
OHM Load.