SECTION 5: TROUBLESHOOTING GUIDE
82
EPI800 Manual.doc
EPI 800 MANUAL
2001 Vision Microsystems Inc.
5. With dimmer control applying full power to DPU backlight power
input, CAREFULLY connect ONE indicator to display cable on the
connector closest to DPU (this eliminates breaks that may be in
cable further away). If the indicator lights up, then the first
connector position AND indicator lighting circuitry are functional.
Test the remaining indicators on this display connector.
If only some indicators are illuminated :
6. Shut off power. Remove the indicators that do not work.
7. Take a known working indicator and test each of the different
connector positions on the display cable. Be sure to turn on full
dimmer power after plugging into each position. If certain positions
test bad, then a new cable will have to be fabricated. If certain
indicators test bad, contact us for assistance.