SECTION 4: INSTALLATION REFERENCE
58
EPI800 Manual.doc
EPI 800 MANUAL
2001 Vision Microsystems Inc.
APPENDIX C: DPU P2 Connector Harness Fabrication
Step 1. Determine required lengths for each thermocouple extension
cable and cut it to this dimension (plus a little extra).
Step 2.
Carefully remove 1 ¼” of outer insulation.
Step 3.
Remove 1/8” of the wire insulation on both leads.
Step 4. Apply NOKORODE
Flux to these leads, otherwise the solder
will not bond to the wire properly. (NOTE: Read caution
statements and directions on container before use).
Step 5. Crimp pin onto wire. See APPENDIX G: Recommended Tools.
Step 6. Carefully solder the area of the crimp and wire.
Step 7. Repeat Step 1 through Step 6 until all wires are done.
Step 8. Thoroughly wash all contacts and crimping tool with water to
remove all flux residues and let dry.
Step 9. Select a grommet that TIGHTLY fits the bundle of cables you are
installing.
Step 10. Feed the pins through the larger diameter of the grommet. Insert
the pins into the connector according to TABLE 2: DPU Harness
P2 Connector Wiring. Make sure pin properly locks in place (it
should click when inserted). Test this by trying to gently pull it
back out.
Step 11. Place half of the backshell onto the connector. Position the
grommet into the backshell so that the larger outside diameter is
located in the back groove. Caution: make sure no wires are
stretched tight at the pins. There should be a slight amount of
slack otherwise the wires may separate from the pins.
Step 12. Add the second half of backshell. Be sure to insert the retaining
screws and clips then tighten down the 2 screws and nuts to
secure the backshell.
The other ends of the cable wires are now ready for attachment to the
transducer connectors. NOTE: You may need to install and route the
harness in the aircraft before doing this next procedure. Install the
connectors according to the guidelines contained in ‘APPENDIX A:
Transducer Connector Wiring Techniques