Technical Data
34
999.994.729.10-en-2.3
© Vision & Control GmbH 2017
5.4.3 Digital I/O card ADLINK
The device has an external digital I/O interface 16 IN / 16 OUT, NPN for the
configuration "Digital I/O card ADLINK”. The digital on-board I/O interface is
disabled when using this configuration.
1
Image 17: Expansion card ADLINK
(1)
Expansion card ADLINK
Characteristics
•
Installed by manufacturer
•
NPN-Open Collector
•
Connector: 50-pin SCSI-II Connector