vicosys
®
5400
Technical Data
22
999.994.729.10-en-2.3
© Vision & Control GmbH 2017
Status indicators
LED
Colour Status
Description
Off
No data transmission
LED 1
Green
On
Send / Receive data
Off
Ethernet port disconnected / not connected
LED 2
Yellow
On
Ethernet port connected
5.3.2 RS232 interfaces
The device has two RS232 interfaces:
DVI
LAN 2
USB
CAN 2
CAN 1 / Serial 2
LED
CAN 1
CAN 2
LED
- R
+
V
D
C
Serial 1
LAN 1
CFAST
HD PWR
RST PWR
I/O
1
2
Image 7: RS232 interfaces
(1)
Serial 1
(2)
Serial 2
Characteristics Serial 1 (RS232 1)
•
Serial communication with a process computer or the PC.
•
The baud rate is set in the factory to 9.600 kbit/s.
•
The baud rate can be adjusted with the operating software vcwin pro.
Characteristics Serial 2 (RS232 2)
•
Operation of the device using the keypad (accessories).
•
The baud rate is factory-set.
•
The baud rate cannot be changed.