5300
Commissioning
6.3.8 Connect the supply voltage
NOTICE
Destruction caused by potential differences.
•
Ensure that the device is properly grounded (equipotential bonding).
Connect the supply voltage
The voltage is supplied via the 3-pin operating voltage connector (scope of
delivery) on the device.
CAN 2
CAN 1 / Serial 2
LED
CAN 1
CAN 2
LED
- R
+
V
D
C
CFAST
HD PWR
RST PWR
I/O
1
+V
DC
GND
Image 21: Operating voltage connector
(1)
Operating voltage connector
1. Ensure that the supply voltage is switched off.
2. Unscrew the operating voltage connector from the device.
3. Connect the positive voltage (plus) to +V
DC
and the negative voltage
(ground) to GND.
Pin
Signal
Description
1
+ V
DC
Supply voltage
2
NC
Do not use
3
2
1
3
GND
Ground
4. Plug the operating voltage connector to the device and tighten the screws.
© Vision & Control GmbH 2021
999.994.347.10-en-2.7
51