Commissioning
6.3.7 Connect the digital I/O interface (Digital I/O card
ADLINK)
NOTICE
Destruction caused by potential differences
•
The ground potential (GND) of the digital inputs and outputs of the device
must be connected to the ground potential (GND) of the control voltage of
the device to be controlled.
Connecting
Die zum Anschluss benötigten Komponenten erhalten Sie als Zubehör.
"Accessories for the option Digital I/O card ADLINK", page 12
1. Connect the I/O cable 50-pin SCSI-II with the SCSI-II connector of the
expansion card.
2. Connect the other end of the cable with the SCSI-II-50-pin terminal block.
3. Connect the ground potential (GND) of the digital inputs and outputs of the
device with the ground potential (GND) of the control voltage of the device
to be controlled.
4. Connect the digital I/Os of the device to be controlled to the SCSI-II-50-pin
terminal block.