Technical Data
5.3.2 RS232 interfaces
The device has two RS232 interfaces:
DVI
LAN 2
USB
CAN 2
CAN 1 / Serial 2
LED
CAN 1
CAN 2
LED
- R
+
V
D
C
Serial 1
LAN 1
CFAST
HD PWR
RST PWR
I/O
1
2
Image 7: RS232 interfaces
(1)
Serial 1
(2)
Serial 2
Characteristics Serial 1 (RS232 1)
•
Serial communication with a process computer or the PC.
•
The baud rate is set in the factory to 9.600 kbit/s. The baud rate can be
adjusted with the operating software vcwin.
Characteristics Serial 2 (RS232 2)
•
Operation of the device using the keypad (accessories).
•
The baud rate is factory-set. The baud rate cannot be changed.
Parameter
Parameter
Min
Nom
Max
Baut rate
9.6 kBit/s
(1)
115.2 kBit/s
Protocol
Internal protocol
Number of bits
8
Number of stop bits
1
Parity
none
Flow control
none
Galvanic decoupling
non-existent
1)
Factory setting