![Vision & Control 4-21-185 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/vision-and-control/4-21-185/4-21-185_instructions-for-use-manual_1031466025.webp)
vicosys
®
6300
Technical Data
5.5.4 PROFINET card HILSCHER
In the configuration "PROFINET card HILSCHER", the device has a PROFINET interface for
process data exchange in a PROFINET network.
C
H
0
S
Y
S
S
F
B
F
L
IN
K
R
X
/T
X
C
H
1
L
IN
K
R
X
/T
X
1
Image 18: Expansion "PROFINET card HILSCHER"
(1)
PROFINET card HILSCHER, Model: CIFX 50E-RE
Characteristics
•
PROFINET IO Device
•
Conformance Class CC_B
•
Net Load Class III
•
PROFINET RT
Status indicators
LED
Colour
Status
Description
Green
On
Operating system running
Green /
Yellow
Flashing
Second stage bootloader is waiting for
firmware
Yellow
On
Bootloader netX (= romloader) is waiting for
second stage bootloader
SYS
Off
Power supply for the device is missing or
hardware defect
Off
No error
Flashing
DCP signal service is initiated via the bus
SF
System
Failure
Red
On
Watchdog timeout; channel, generic or
extended diagnosis present; system error
Off
No error
Flashing
No data exchange
BF
Bus Failure
Red
On
No configuration; or low speed physical link; or
no physical link
On
The device is linked to the Ethernet
Link
Ch0 / Ch1
Green
Off
The device has no link to the Ethernet
Flickering (load
dependant)
The device sends/receives Ethernet frames
RX / TX
Ch0 / Ch1
Yellow
Off
The device does not send/receive Ethernet
frames
© Vision & Control GmbH 2022
999.995.428.10-en-2.1
25