![Vision & Control 4-21-185 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/vision-and-control/4-21-185/4-21-185_instructions-for-use-manual_1031466018.webp)
vicosys
®
6300
Technical Data
5.4.2 RS232 interfaces
The device has two RS232 interfaces:
TX1
RX1
TX2
RX2
2
1
5
6
8
7
1
4
2
1
2
1
Image 8: Basic device: RS232 interfaces
(1)
Serial 1
(2)
Serial 2
Characteristics Serial / RS232
•
Serial communication to the process computer.
•
Serial communication with peripheral devices.
•
The baud rate is set in the factory to 9.600 kbit/s. The baud rate can be adjusted with the
operating software vcwin.
Parameter
Parameter
Min
Nom
Max
Baud rate
9.6 kBit/s
(1)
115.2 kBit/s
Number of bits
8
Number of stop bits
1
Parity
None
Flow control
None
Galvanic decoupling
Non-existent
1)
Factory setting
5.4.3 USB interfaces
NOTICE
Overheating due overload
•
Each USB port can deliver a maximum output current of 900 mA.
•
Ports 1/2, 3/4, 5/6 and 7/8 are each secured with 1800 mA.
ADVICE
Data loss due to incorrect disconnecting of devices!
•
Always unmount USB storage devices before switching off or disconnecting.
•
Unmount in vcwin:
Using the instruction
External Storage Device - Unmount USB Device
.
18
999.995.428.10-en-2.1
© Vision & Control GmbH 2022