background image

creating machine vision

 VISION & CONTROL

Instructions for Use

DL60x60-IR850/24V

LED area light, diffuse illumination,

Luminous colour: Infrared - 850 nm

Instructions for Use

DL60x60-IR850/24V

LED area light, diffuse illumination,

Luminous colour: Infrared - 850 nm

999.995.555.10-en-1.0

© Vision & Control GmbH 2019

Содержание 1-20-304

Страница 1: ...s for Use DL60x60 IR850 24V LED area light diffuse illumination Luminous colour Infrared 850 nm Instructions for Use DL60x60 IR850 24V LED area light diffuse illumination Luminous colour Infrared 850...

Страница 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Страница 3: ...0x60 IR850 24V 1 20 304 Product Identification Designation Description DL LED area light diffuse illumination 60x60 Dimensions light emitting surface 60 mm x 60 mm IR850 Wavelength Infrared 850 nm 24V...

Страница 4: ...ion 13 4 1 Device Views 13 4 2 Notices on the device 14 5 Technical Data 15 5 1 General Parameters 15 5 2 Electrical Parameters 16 5 3 Photometric Parameters 17 5 4 Conditions for Operation Storage an...

Страница 5: ...DL60x60 IR850 24V Vision Control GmbH 2019 999 995 555 10 en 1 0 5...

Страница 6: ...uture reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potenti...

Страница 7: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Страница 8: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Страница 9: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Страница 10: ...ce and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric sh...

Страница 11: ...16 Cable with M5 socket 4 pin straight 10 m Connection cable with 4 pin M5 socket and open cable end with ferrules 4 x 0 14 PUR IP67 straight socket 1 11 102 Cable with M5 socket 4 pin angled 2 m 1 11...

Страница 12: ...y and Accessories Mounting systems Designation Description Order no AL DL60x60 mounting for defined or rotatable and swiveling mounting of AL DL60x60 series incl fixing screws 1 20 070 12 999 995 555...

Страница 13: ...scription 4 DEVICE DESCRIPTION 4 1 Device Views 1 2 3 4 Image 1 Device view 1 Light emitting surface 2 4 pin M5 connector 3 Casing 4 2 x M3 mounting hole depth 6 mm on each side Vision Control GmbH 20...

Страница 14: ...ing instructions are provided on the device 2 1 1 Type plate 2 Pin assignment Type plate Type XXXXXXXXX No TTTJJNNN 2 3 1 4 Image 2 Type plate 1 Manufacturer information 2 Device designation 3 Serial...

Страница 15: ...mensions light emitting surface 60 mm x 60 mm Weight 96 g Degree of protection IP IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk group 0 exempt group Connector...

Страница 16: ...er consumption at UO 24 V DC 4 2 W 1 Input voltage OFF 0 V 2 7 V Input current OFF 0 mA 2 mA Input voltage ON 3 7 V 30 V Input current ON 5 mA 10 mA Switch input ON OFF Input delay tD 150 s 1 The nomi...

Страница 17: ...860 nm Centroid Wavelength centroid 850 nm Spectral bandwidth 30 nm Continuous operation switchable Radiance 110 W m sr Spectral Emission Relative spectral emission Wavelength nm 0 20 40 60 80 100 60...

Страница 18: ...riginal packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature 0...

Страница 19: ...tor 7 2 60 65 60 65 light emitting surface 2 x M3 depth 6 on both sides 25 20 7 75 23 pin assignment type plate 20 25 2 x M3 depth 6 on both sides 5 type plate height 0 1 Image 4 Technical drawings di...

Страница 20: ...ogether with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion pock...

Страница 21: ...state To mount the device tapped holes are located at the sides 1 1 2 2 Image 5 Mounting holes 1 2 x M3 tapped hole on both sides Maximum screw in depth 6 mm Distance between the tapped holes 25 mm 2...

Страница 22: ...ay only be performed in the off and de energised state NOTICE Cable damage Comply with the specified minimum bending radius Cables must generally be mounted with a strain relief clamp Use cables corre...

Страница 23: ...the pin assignment Pin assignment 1 2 4 3 Image 6 M5 4 pin male plug Connection diagram V GND 1 3 4 BU BK BN ON OFF Pin Core colour Signal Description 1 BN brown V Operating voltage 2 WH white NC Do n...

Страница 24: ...re flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzling...

Страница 25: ...ous operation The lighting is switched on by setting the ON OFF signal after the delay time td Resetting the ON OFF signal turns off the lighting Continuous operation switchable The switchable continu...

Страница 26: ...s t Lighting t Switching signal td td tON ts Continuous operation Continuous operation td td tON switchable ts Exposure time of the camera tON Power on time td Delay time Min Nom Max Delay time td 150...

Страница 27: ...side with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected an...

Страница 28: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Страница 29: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Страница 30: ...al environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and measurem...

Страница 31: ...DL60x60 IR850 24V Vision Control GmbH 2019 999 995 555 10 en 1 0 31...

Страница 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Отзывы: