background image

 
 

 

9B 

 

Program Shows

 

Press the 

MENU

 button up to when the 

  is shown on the display. Press the 

ENTER

 

button and select the 

  mode, Press the 

ENTER

 button and the display will blink. Use 

the 

DOWN

 and 

UP

 button to select the 

  (Show 17) ,

Show 18

or 

Show 19

. Once the show has been selected, press the 

ENTER

 button to enter program setting. 

Use the 

DOWN

 and 

UP

 button to select 

(length, the steps, you choose from the total 

amount of steps, you want to run, for example, if the total amount of steps you set is 50, you can 

choose only first 1-10 steps to run). 

 (step), select 

 to set 

 (color) and 

 

(white) and 

  (dimmer) for every step. Automatically return to the main functions without 

any change after one minute. To go back to the previous functions without any change press the 

MENU

 button. 

 

 

Manual Mode

 

Press the 

MENU

 button up to when the 

  is shown on the display. Press the

 ENTER

 button 

and the display will blink. Use the

 DOWN

 and 

UP

 button to select the 

Red

,

Green

,

Blue

,

White

Dimmer

 or 

Strobe

Once selected, press the

 ENTER

 button to setup, then use the

 DOWN

 and 

UP

 button to adjust the 

value (0~255) or automatically exit menu mode without any change after one minute. To go back to 

the functions without any change press the 

MENU

 button. 

 

 

White Balance

 

Press the 

MENU

 button up to when the 

 is showing on the display. Pressing the

 

ENTER

 button and the display will blink. Use the

 DOWN

 and 

UP

 button to select the 

Red

Green

or 

Blue

mode. Once the mode has been selected, press the 

ENTER

 button to setup or automatically return to the main functions without any change after one 

minute. To go back to the previous functions without any change press the 

MENU

 button. 

 

Содержание BW-903 RGBW

Страница 1: ...BW 903 RGBW User Manual Please read the instructions carefully before use...

Страница 2: ...hical Specfications 3 3 How To Set The Fixture 5 3 1 Control Panel 5 3 2 Main Functions 6 4 How To Control The Unit 12 4 1 DMX Controller 12 4 3 DMX 512 Configuration 14 5 DMX512 Connections 15 6 Trou...

Страница 3: ...the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y Maximum ambient te...

Страница 4: ...t is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit...

Страница 5: ...rmance 9000 Lumen Output 1KHz refreshing frequency flicker free under HD camera Special design of ventilation system BW 903 RGBW running full duty cycle y Input Voltage AC 100 240V 50 60Hz y Power Con...

Страница 6: ...o go backward in the selected functions 4 UP To go forward in the selected functions 5 ENTER To confirm the selected functions 6 POWER IN Water proof connectors for power input 7 POWER OUT Water proof...

Страница 7: ...TER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press the MENU button The main functions a...

Страница 8: ...7B...

Страница 9: ...de Select the press the ENTER button and the display will blink Use the DOWN and UP button to select the show 1 show 19 Once select press the ENTER button to setup press the ENTER button will blinking...

Страница 10: ...ns without any change press the MENU button Manual Mode Press the MENU button up to when the is shown on the display Press the ENTER button and the display will blink Use the DOWN and UP button to sel...

Страница 11: ...e press the ENTER button to confirm then use the DOWN and UP button to adjust the dimmer 1 9 Notice If flash mode is selected press the ENTER button to confirm then use the DOWN and UP button to selec...

Страница 12: ...ock Press the MENU button up to when the is showing on the display Press the ENTER button and the display will blink Use the DOWN and UP button to select the lock the key board or normal Once select p...

Страница 13: ...gain 4 How To Control The Unit You can operate the unit by DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once Every time yo...

Страница 14: ...13B press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units...

Страница 15: ...14B 4 3 DMX 512 Configuration 4 5 7 Channels Mode...

Страница 16: ...e or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit whe...

Страница 17: ...work no light Incorrect mains voltage Measure the mains voltage on the main connector Incorrect DMX cable connection Check DMX connectors and cables to see if link properly Repair or replace damaged...

Страница 18: ...g frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics y Clean with soft cloth...

Страница 19: ...th the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598...

Страница 20: ......

Отзывы: