General System Parameters
SYSTEM > SET > OPER
VT300 Technical Manual, Rev. A4
42
Doc # TM-VT300-EN
# Parameter
Description
Values
05 WAIT
UNLOAD
Wait for weight to unload before printing again.
YES specifies that after printing, the indicator should not
allow the user to print again, until the scale has been
unloaded.
NO specifies that the user should be able to print again,
even if the scale has not been unloaded.
YES, NO
06 1stW
Print first weighing ticket automatically.
YES specifies that the first weighing data should be
automatically printed.
NO specifies that the user should be prompted to print the
first weighing ticket, and will have the option of canceling
the printing.
Regardless of what is selected here, first weighing data is
saved to memory, unless
WEIGHING MEM
=NO.
YES, NO
07 USER
FORMS
Custom weighbridge descriptions and printing
formats.
YES specifies that service personnel should be able to
define custom weighbridge descriptions (reference codes)
and custom print formats.
NO specifies that only the default weighbridge descriptions
and print formats should be available.
YES, NO
08 KEY
IN
TIME
Time for character selection entry
(in 0.1 seconds).
00 disables alpha characters.
0-99
09 BRIGHTNESS
LCD backlight brightness.
Low is the least bright, MID1
is brighter, MID2 is brighter still, HIGH is brightest.
LOW, MID1,
MID2, HIGH
10 DATE
FORMA
Date format.
Select either day-month-year (D-M-Y) or
month-day-year (M-D-Y). In either case, the numbers in
the date will be separated by hyphens (“-”).
D-M-Y, M-D-Y
11 AUTO
PWR
OFF
Power off interval.
Specifies the idle time, in minutes,
that should pass before the indicator automatically
switches itself off.
00-99
00=disable
power off