Transmitter WST 3
11
5. Edit the transmitter resolution.
With this parameter, the number of decimals and the resolution of the last digit
of the measurement value are defined.
This parameter influences all measurement values using the measurement unit.
Press
+
to get parameter ‘Resolution’ displayed.
Resolution
0.1 kg
Press
if the resolution should be edited, and make the editing
like in point
3.
on page 10.
In the following examples, resolution with two decimals is used.
6. Edit the transmitter capacity (numeric parameter).
This parameter defines the capacity of the transmitter, i.e. the weight value that
corresponds to full range at the analogue output.
Press
+
to get the parameter ‘Capacity’ displayed.
Capacity
500.00 kg
Press ENTER to make editing possible.
Capacity
0500.00 kg
A cursor starts flashing to the left on the parameter value line, indicating which digit
that can be edited.
Press ENTER to move the cursor, step by step to the right in the parameter value, to
the digit to edit.
Capacity
0500.00 kg
Press
+
(or
–
) until the wanted digit value is displayed (1 in this example).
Capacity
0100.00 kg
(repeated)
When necessary, press ENTER again to move the cursor to another digit to edit.
Press ENTER for 2 seconds when the capacity parameter value is correct.
2 seconds
Capacity
100.00 kg
The cursor disappears, and the edited parameter value becomes active.