14 / 32
eco-PEN700 3D
4.1.3
Feeding material and bleeding the dispenser for the first time
Preparation
Connect the material supply (feed line, cartridge) to the material inlet (12) of the dispenser.
The dispenser can be bled in one of two ways after the medium has been supplied.
Version A
(e.g. supply via a hose, closed cartridge)
Tip:
Connecting a hose can protect the dispenser from being wetted with the medium.
Move the dispenser to a position in which
the end piece (3) points upwards.
Connect the drive unit to the power supply
and run slowly until the material escapes
from the outlet nozzle (attached Luer-Lock
needle) without bubbles.
12
3
Fig. 4
Содержание Preeflow eco-PEN700 3D
Страница 1: ...OPERATION MAINTENANCE MANUAL eco PEN700 3D ...
Страница 30: ...30 32 INST 002756 A eco PEN700 3D Notes ...
Страница 31: ...31 32 INST 002756 A eco PEN700 3D Notes ...