Important safety instructions 

 

VISATEC flash light systems should exclusively be utilised for professional 
flash light systems by qualified personnel. Before starting up your flash 
light equipment read carefully all the information in your operating 
instruction. The safety instructions in the operating instructions must be 
imperatively followed! 
 

• 

Read and understand all instructions before using! 

• 

Remove the transport protection and the packing material 

• 

Close supervision is necessary when any appliance is used near children. Do not 
leave the flash light appliance unattended while in use! 

• 

Flash light contains, similar to sunlight, a specific portion of UV radiation! The 
undesirable side effects on skin and eyes are considerably reduced by using flash 
tubes or protecting glasses with UV safety measures! Nevertheless, taking pictures at 
close distances with unprotected skin and eyes should be avoided! Also avoid eye 
contact with the light source! The maximum daily UV radiation according to IEC 
60335-2-27 / DIN 5031-10 is: 50 J/m

2

. This value should not be exceeded! 

• 

With due allowance for heat radiation, the distance between the monolight and a 
person or between the monolight and inflammable respectively heat sensitive 
surfaces should be at a minimum distance of 1 m! 

• 

Prior to replacing flash tubes, halogen lamps, protecting glasses or fuses, disconnect 
the monolight and the lamp from the power supply! Prior to replacing the halogen 
lamp or the flash tube, the monolight should cool down for 10 min.! 

• 

VISATEC flash light systems should only be equipped with original VISATEC flash 
tubes, original VISATEC combustible and packing material, original VISATEC 
accessories, and also original VISATEC spare parts! 

• 

VISATEC flash light systems, lamps and accessories meet an extremely high safety
standard! When connecting VISATEC units to accessories of other brands, integrated 
safety measures may become ineffective! Due to different design features and
contact assignment of the products of other brands, the user himself/herself may
even be at risk. We offer no guarantee and accept no liability for damages which may
be caused by this type of usage! 

• 

To avoid the risk of fire, electric shock or injury to persons utilise exclusively the 
accessory recommended by the manufacturer! 

• 

Check that the mains voltage corresponds to the information on the type plate of the 
unit! 

• 

The flash light equipment is designed for use in dry conditions and in an ambient 
temperature from 0°C to 35°C! The flash light equipment has to be protected from 
wetness, condensation, from dripping and splash water, humidity, dirt, sand, metal 
chips and exposure to dust! 

• 

Protect the flash light equipment from electromagnetic fields, shock and vibration! 

• 

Protect the flash light equipment from heat and frost! If the monolight freezes 
continuous loss of power output and serious technical damage can result! 

Содержание LOGOS 1600

Страница 1: ...www visatec com Operating Instructions Bedienungsanleitung Mode d emploi LOGOS 800 LOGOS 1600...

Страница 2: ...a safe place and pass them on to further users if necessary Observe the safety instructions Contents Page Important safety instructions 2 Controls and displays 5 1 Application LOGOS 7 2 Start up 7 3...

Страница 3: ...sses or fuses disconnect the monolight and the lamp from the power supply Prior to replacing the halogen lamp or the flash tube the monolight should cool down for 10 min VISATEC flash light systems sh...

Страница 4: ...or twisted must be replaced The unit must only be connected to an earthed socket or an emergency power generator and an earthed extension cable If an extension cable is necessary a cable with a curren...

Страница 5: ...ce the risk of electric shock do not open this appliance but take it to a qualified service person when service or repair work is required Incorrect reassembly can cause electric shock when the applia...

Страница 6: ...usable as connection socket for computer link 2 Sync socket 3 Photocell on off 4 Modelling light on off 5 Test release ready display green 6 Connection socket for mains cable 7 Fuse 8 Energy control u...

Страница 7: ...6 Front panel for LOGOS 800 1600 1 2 4 5 8 9 7 10 121314151617 11 aux aux prop seq buz slow dim unit test mod sync com sync cell 18 6 3...

Страница 8: ...se injuries For this reason we recommend to touch the unit only on the handle at the rear or on the stand adapter The distance between the monolight and a person or between the monolight and inflammab...

Страница 9: ...odelling light can be set proportionally to the flash intensity To assure proportionality also when units with different power output ratings are operated together the units have various proportionali...

Страница 10: ...tilting Afterwards pull the flash tube straight along the lamp axis so that the halogen lamp can be replaced Taking the service life into consideration the halogen lamp should not be handled with bare...

Страница 11: ...D goes out until the unit is fully charged again 6 2 The audible ready signal buzzer sounds when the unit is at 100 charge It may be switched on or off chapter 7 6 3 Audible fault signal When the flas...

Страница 12: ...the setting changes in intervals of ten Each release signal triggers the selected number of flashes A current sequence can be aborted by a long pressure on the energy control keys up down 8 or by swit...

Страница 13: ...optimal colour temperature For your security only original VISATEC flash tubes must be used For safety reasons never operate a unit without protecting glass in place If the monolight LOGOS 800 is use...

Страница 14: ...keys for approx 5 seconds the LED array prop seq dim buz slow unit blinks to indicate that you are in the programming mode Additionally the LED of the mod key is lit The digital display shows the func...

Страница 15: ...utput 1 3 f stop which results in a longer service life of the halogen lamp If this function is activated the digital display shows the value on 12 Protective facilities Fault indication 12 1 Cooling...

Страница 16: ...it is switched off 12 6 Monitoring of the modelling light If the monolights LOGOS are connected to 200 V 240 V mains voltage after previously having been operated on 100 V 120 V mains voltage they wil...

Страница 17: ...t is at your disposal You will find the complete overall view in the VISATEC system catalogue 15 1 Mounting of barn doors The barn doors are attached onto the fastening braces on the reflector 16 Serv...

Страница 18: ...ols Illuminated digital display LED line and keyboard Control range of flash energy Japan f stop less Over 4 f stops in 1 10 f stop increments 1 16 Modelling light Halogen max 150 W Proportional to fl...

Страница 19: ...ations are at your disposal 18 1 Modification to LOGOS RFS There is the possibility to modify LOGOS monolights later on with a RFS interface The modification will be made by the customer service centr...

Страница 20: ...9 336 and 99 5 ERM EN 300 220 1 3 EMC EN 301 489 1 3 EN 60950 EN 50371 FCC Part 15 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...

Страница 21: ...VISATEC Postfach CH 4123 Allschwil 1 Schweiz Printed in Switzerland 07 07...

Отзывы: