Visatec LOGOS 1600 Скачать руководство пользователя страница 13

 

- 12 - 

 

7.6 

Studio / appliance address (unit) 

 

The monolights LOGOS are also available as versions with built-in RFS Interface (

R

adio 

F

requency 

S

ystem). For remote control respectively flash release via radio, an individual 

appliance address and a studio desk top (remote control channel) can be assigned to 
each RFS unit by means of the function “unit“ (18). 
 
To carry out the settings, dial the LED “unit“ using the “aux“ key (11). The digital display 
(10) shows the letter “U“, followed by an appliance number between 1 and 8. By briefly 
pressing the energy control keys “up / down“ (8), the required value can be selected. 
When pressing again  the “aux“ key (11), the digital display (10) shows the letter “C“, 
followed by a studio number between 1 and 8. By briefly pressing the energy control keys 
“up / down“ (8), the required value can be selected. 

 
 

8.  Flash tube 

 

The flash tube is coated to ensure an optimal colour temperature. For your security, only 
original VISATEC flash tubes must be used. For safety reasons, never operate a unit 
without protecting glass in place. 
 
If the monolight LOGOS 800 is used for longer flash sequences, we recommend to 
employ the flash tube for LOGOS 1600 / SOLO 1600B - Art. no. 54.301.00. 

 

8.1 

Replacing the flash tube 

 

Attention: 

Prior to each exchange of the flash tube, the monolight must be fired 
down and immediately afterwards disconnected from the mains! Before 
exchanging the flash tube, let the monolight discharge and cool down for 10 
min.! 
 

The flash tubes are plug-in. 

 

1.)  To replace the flash tube, discharge the unit by flashes, disconnect it from power 

supply and let it cool off for ten minutes (to discharge the flash capacitors). 

 
2.)   Remove the protecting glass. 
 
3.)   First pull out the ignition cable and then the flash tube (do not touch the flash tube 

with bare hands). 

 
4.)  Insert the new flash tube. 
 
5.)   Re-insert the ignition cable. 
 
6.)   Replace the protecting glass. 
 
7.)   Connect the unit to the power supply, now it is ready for use again. 

Содержание LOGOS 1600

Страница 1: ...www visatec com Operating Instructions Bedienungsanleitung Mode d emploi LOGOS 800 LOGOS 1600...

Страница 2: ...a safe place and pass them on to further users if necessary Observe the safety instructions Contents Page Important safety instructions 2 Controls and displays 5 1 Application LOGOS 7 2 Start up 7 3...

Страница 3: ...sses or fuses disconnect the monolight and the lamp from the power supply Prior to replacing the halogen lamp or the flash tube the monolight should cool down for 10 min VISATEC flash light systems sh...

Страница 4: ...or twisted must be replaced The unit must only be connected to an earthed socket or an emergency power generator and an earthed extension cable If an extension cable is necessary a cable with a curren...

Страница 5: ...ce the risk of electric shock do not open this appliance but take it to a qualified service person when service or repair work is required Incorrect reassembly can cause electric shock when the applia...

Страница 6: ...usable as connection socket for computer link 2 Sync socket 3 Photocell on off 4 Modelling light on off 5 Test release ready display green 6 Connection socket for mains cable 7 Fuse 8 Energy control u...

Страница 7: ...6 Front panel for LOGOS 800 1600 1 2 4 5 8 9 7 10 121314151617 11 aux aux prop seq buz slow dim unit test mod sync com sync cell 18 6 3...

Страница 8: ...se injuries For this reason we recommend to touch the unit only on the handle at the rear or on the stand adapter The distance between the monolight and a person or between the monolight and inflammab...

Страница 9: ...odelling light can be set proportionally to the flash intensity To assure proportionality also when units with different power output ratings are operated together the units have various proportionali...

Страница 10: ...tilting Afterwards pull the flash tube straight along the lamp axis so that the halogen lamp can be replaced Taking the service life into consideration the halogen lamp should not be handled with bare...

Страница 11: ...D goes out until the unit is fully charged again 6 2 The audible ready signal buzzer sounds when the unit is at 100 charge It may be switched on or off chapter 7 6 3 Audible fault signal When the flas...

Страница 12: ...the setting changes in intervals of ten Each release signal triggers the selected number of flashes A current sequence can be aborted by a long pressure on the energy control keys up down 8 or by swit...

Страница 13: ...optimal colour temperature For your security only original VISATEC flash tubes must be used For safety reasons never operate a unit without protecting glass in place If the monolight LOGOS 800 is use...

Страница 14: ...keys for approx 5 seconds the LED array prop seq dim buz slow unit blinks to indicate that you are in the programming mode Additionally the LED of the mod key is lit The digital display shows the func...

Страница 15: ...utput 1 3 f stop which results in a longer service life of the halogen lamp If this function is activated the digital display shows the value on 12 Protective facilities Fault indication 12 1 Cooling...

Страница 16: ...it is switched off 12 6 Monitoring of the modelling light If the monolights LOGOS are connected to 200 V 240 V mains voltage after previously having been operated on 100 V 120 V mains voltage they wil...

Страница 17: ...t is at your disposal You will find the complete overall view in the VISATEC system catalogue 15 1 Mounting of barn doors The barn doors are attached onto the fastening braces on the reflector 16 Serv...

Страница 18: ...ols Illuminated digital display LED line and keyboard Control range of flash energy Japan f stop less Over 4 f stops in 1 10 f stop increments 1 16 Modelling light Halogen max 150 W Proportional to fl...

Страница 19: ...ations are at your disposal 18 1 Modification to LOGOS RFS There is the possibility to modify LOGOS monolights later on with a RFS interface The modification will be made by the customer service centr...

Страница 20: ...9 336 and 99 5 ERM EN 300 220 1 3 EMC EN 301 489 1 3 EN 60950 EN 50371 FCC Part 15 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...

Страница 21: ...VISATEC Postfach CH 4123 Allschwil 1 Schweiz Printed in Switzerland 07 07...

Отзывы: