INSTALLING THE PURIFICATION PLATE

Holding the Purification Plate by the ceramic, slowly insert it into the Purification Plate Slot, ensuring that the Purification 
Plate is sliding into the grooves on either side.

NOTE

: About halfway in, the Purification Plate Connectors are parted. Continue sliding the Purification Plate into the 

Purification Plate Slot until there is approximately one inch of the Purification Plate remaining outside of the Purification 
Plate Slot and significant resistance is met. Be careful not to force the Purification Plate further into the Purification Plate Slot 
as this could seriously damage your unit.

INSTALLING THE FILTER ASSEMBLY

1.  Hold the Filter Assembly with the larger flat side facing the interior of the unit. A sticker reading, “Caution: Reinstall Filter 

After Cleaning,” is located on the opposite side of the Filter Assembly. This sticker should be visible when you install the 
Filter Assembly.

2.  Insert the bottom of the Filter Assembly into the tabs on the rear of the unit and then seat the Filter Assembly on the rear 

of the unit. 

 

CAUTION

: If the user fails to insert the Filter Assembly into the tabs appropriately, disassembling the unit in the future 

could be extremely difficult.

3.  Screw the two brass thumbscrews into their holes at the top corners of the Filter Assembly.

INSTALLING THE REAR COVER

1.  Place the tab at the top of the Rear Cover into the hole at the top of the Filter Assembly then lay the Rear Cover flat 

against the rear of the unit until the tabs on the sides of the Rear Cover click into place on the unit.

2.  Carefully insert the Rear Cover screw into its hole on the Rear Cover (above the Power Cord Port) and tighten.

OPTIONAL PRE-FILTER

Содержание MINI

Страница 1: ...ace Sanitiser User Manual TABLE OF CONTENTS PRODUCT INTRODUCTION 2 FOUR TECHNOLOGIES 3 SPECIFICATIONS WARNINGS 3 DIAGRAMS 4 SETUP 5 CONTROLS 6 OPERATIONS 7 DISASSEMBLY ASSEMBLY 8 CLEANING 12 TROUBLESHOOTING 13 ...

Страница 2: ... with air purifier to help keep the purifier clean while at the same time filtering out particles Unlike expensive HEPA filters the electrostatic filter is washable and can be used over and over again NEEDLEPOINT IONIZATION The air purifier generates a continuous stream of millions of negative ions that circulate throughout the home These ions charge particles such as dust dander or bacteria causi...

Страница 3: ... NORMAL Mode Output 0 02 ppm ozone ambient room concentration PURIFICATION PLATE HIGH Mode Output 25 360 mg ozone per hour IONIZATION 6 KV DC Needle Ion generator 24 30 KV 20 30 KH3 Ion generator pulsator WARNINGS Review this list before use and performing any maintenance or cleaning of your unit WARNING Never operate unit near heat source open flame or flammable combustible fluids WARNING Do not ...

Страница 4: ...nt 2 Front Grill 3 Control Panel 1 Rear Cover Screw 2 Rear Cover Clasps 3 Power Adapter Inlet 1 Rear Cover 2 Unit Rear 3 Unit Front REAR OF UNIT Rear Cover Removed REAR OF UNIT Filter Assembly Removed 2 1 1 2 3 4 1 1 Brass Thumbscrews 2 Filter Assembly 1 PCO Cell 2 PCO Cell Nuts 3 PCO Cell Connector 4 Purification Plate ...

Страница 5: ...79 m2 of space For example Suppose you have a 232 m2 house The living room is attached to the kitchen three bedrooms the den and a laundry room The kitchen and three bedrooms doors remain open the majority of the time but the laundry room and den usually remain closed off from the rest of the house Together the laundry room and den have a combined area of 46 m2 The area of the environment you woul...

Страница 6: ...icator 5 AWAY ModeTimer Indicator Not for use in occupied room 2 Photocatalytic Oxidation Mode Indicator 6 AWAY ModeWarning Indicator 3 Mode Coverage Indicator 7 REPLACE PLATE REPLACE PCO CELL Replacement Notification Indicator 4 Mode Coverage Warning Indicator 8 PERFORM CLEANING Maintenance Notification Indicator NOTE It is recommended to leave the room vacant for 2 hours after running the unit i...

Страница 7: ...e more to switch the unit back to NORMAL Mode LCD REMINDERS REPLACE PLATE When REPLACE PLATE appears the Purification Plate has reached the end of its useful life and must be replaced To order a replacement contact your distributor Once a replacement has been obtained follow the instructions in DISASSEMBLY ASSEMBLY page 8 to replace your old Purification Plate with your new one REPLACE PCO CELL Wh...

Страница 8: ...lt away from the unit Clean if necessary see Cleaning the Filter Assembly page 10 and set the Filter Assembly aside REMOVING THE PURIFICATION PLATE Grasp the Purification Plate on the ceramic and gently pull it out of the grooves on the sides Clean see Cleaning the Purification Plate page 10 and set the Purification Plate aside REMOVING THE PCO CELL 1 Locate the PCO Cell Power Connector on the rig...

Страница 9: ...r of the unit A sticker reading Caution Reinstall Filter After Cleaning is located on the opposite side of the Filter Assembly This sticker should be visible when you install the Filter Assembly 2 Insert the bottom of the Filter Assembly into the tabs on the rear of the unit and then seat the Filter Assembly on the rear of the unit CAUTION If the user fails to insert the Filter Assembly into the t...

Страница 10: ...10 10 VIRO TECH MINI USER MANUAL REMOVING THE REAR LINT SCREEN REMOVING THE PURIFIER PLATE ACTIVEPURE RCI CELL ...

Страница 11: ...THE POWER CORD 1 Insert the Power Adapter Plug into the rear of the unit 2 Ensure the Power Cord is properly connected to the Power Adapter 3 Insert the Power Plug into a wall outlet TURNING THE UNIT ON Press the Power Button Ensure that the unit s settings are adjusted to suit the environment see OPERATING THE UNIT page 7 ...

Страница 12: ...ust that may accumulate near the ionization needle CLEANING THE PCO CELL Using a compressed air or a vacuum cleaner blow and or vacuum the dust out of the PCO Cell Do not use any liquid to clean the PCO Cell CLEANING THE PURIFICATION PLATE Using a 50 50 mix of warm water and clear ammonia 100 white vinegar can be used in place of water and ammonia soak the Purification Plate for 8 10 hours but do ...

Страница 13: ...e a dim purple glow THE PURIFICATION PLATE GENERATES AN ELECTRICAL ARC AN ARCING NOISE OR A BURNING ODOUR This means the Purification Plate is damaged and must be replaced The unit may or may not display the REPLACE PLATE LCD reminder To order a replacement contact your distributor THE PCO CELL IS NOT LIGHTING UP 1 Ensure the PCO Cell Power Connector is properly seated in the PCO Cell Power Connec...

Страница 14: ...Wilkinson Star Limited Shield Drive Wardley Industrial Estate Worsley Manchester M28 2WD wilkinsonstar247 com 44 0 161 793 8127 viro wilkinsonstar com June 2020 ...

Отзывы: