![Virax 570001 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/virax/570001/570001_user-manual_1029963055.webp)
Page 55
Use the adjusting knob
(4)
to select the desired parameter, P101 to P114. If this value must be adjusted or
displayed, briefly press the adjusting knob
(4)
. The (default) value blinks in the lower display
(9)
.
Use the adjusting knob
(4)
to set the value, and press the adjusting knob
(4)
briefly again. Then the
parameter blinks again in the upper display
(2)
.
To leave the menu, press the release button
(10)
. The values are stored
*
P002
–
Power saving function:
0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off..
3.6.
Set date and time
Close the program by clicking briefly in the upper left corner.
Parameter
name
Description
Default
Unit
min
max
Rights
P001
Remaining energy saver time
99
min
0
99
Welder
P002
*
Power saving function active
0
0
3
Welder
P003
Heating plate temperature offset
5
°C
-25
25
Welder
P004
Pmax for cutting
20
bar
10
50
Welder
P005
Target pressure
1/10 bars
Welder
P006
Target temperature
210
°C
P103
P104
Welder
P007
Timer T1 target value
45
sec
1
1500
Welder
P008
Timer T4 target value
6
min
1
99
Welder
P009
Pstart for cutting
10
bar
0
P004
Welder
P101
Deviation for repumping
5
%
1
50
Master
P102
Lifting time after cutting
10
1/10 sec
0
100
Master
P103
Set temperature (min)
160
°C
0
300
Master
P104
Set temperature (max)
270
°C
0
300
Master
P105
Button lock (yes/no)
5
sec
0
50
Master
P106
Lifting pressure
135
bar
10
160
Master
P107
Full runtime until buzzer goes on
50
1/10 sec
0
200
Master
P100
Change code
8001
Master