Page 36
3.1.1.
Basic unit (fig. A)
1
Movable clamps
3
Spacer with locking notch
2
Sliding clamps
4
Heating element take off device
3.1.2.
Hydraulic unit (fig. B)
1
Automatic button
12
Timer button
2
Pressure button
13
Socket for cutting unit
3
Pressure release button
14
Quick coupling for pipe collar
4
Adjusting knob
15
Quick coupling for plug
5
Cutting button
16
Heating element connector
6
ON/OFF button
17
Electric plug
7
Heating button
18
Emergency OFF
8
« Open » machine
19
Touch screen PC
9
Temperature and time display
20
Oil filling port with dipstick
10
Release button
21
USB connection
11
« Close » machine
22
Basic machine plug and socket device
The hydraulic unit allows the operator to operate the welding machine and perform the functions indicated by
the following symbols::
Turning the hydraulic assembly on and off
Press the „Heating“ button to turn the
heating element on. Set the desired
heating element temperature by pressing the „Heating“ button and
turning the
adjustment knob. The value will be shown in the temperature display, and then
the current value is again shown.
Use the adjustment knob to set the pressure for cutting, aligning, heating and
joining.The value is shown in the „Pressure“ display. Three seconds
after the
settings are made, the current value is shown. Pressing the rotary knob displays
and allows changes to be made to the service parameters.
To bring the clamping elements together, press the release button and „close“
the machine.
Pressure release button
To separate the clamping elements, press the release button and „open“ the
machine.
Press the release button and the cutting button to turn on the cutting unit
socket. Pressure is automatically set to 10 bar and can be increased to a
maximum of 20 bar using the adjusting knob. (In special situations, such as on
slopes, the pressure can be set to a maximum of 50 bar by changing P004.)
Activate the timer by pressing it once. By pressing the button and turning the
adjusting knob, the t1 time can be set in seconds. Pressing the button longer
switches over to t4. By pressing the button and turning the adjusting knob, the
t4 time can be set in minutes. The timer is started manually by shortly pressing