Page 46
The pressure is linearly raised to the appropriate joining pressure.
When joining pressure is reached, the program automatically goes to the joining process and the t4 timer starts.
The upper progress bar shows whether the pressure lies within the correct range (green) or within a permissible
(yellow) tolerance range or whether it lies outside (red) the tolerance range. The time lapse is shown below. The
actual pressure is shown in display (2) and the remaining joining time in display (9).
The pressure is automatically monitored and regulated. If the hydraulic system repumps too often (meaning
there is high pressure loss), have it checked.
Put the heating element back in the storage case.
The welding process is ended after the cooling down time has expired, is stored, a signal sounds and the
pressure is dissipated automatically.