Maintenance
Clean the controller only with soapy water.
Storage
In the event of prolonged non-use, remove the battery from the controller. The controller must be
stored in a frost-free place.
Diagnostics and repairs
The pump does not operate
Diagnostics:
Problem-solving:
The battery is defective or improperly installed.
Install a new 1.5 Volt alkaline battery type AA
–
LR6 as indicated in the photograph, with the
correct polarities. If the problem persists, return
the cotroller to VIRAX After-Sales Service.
The pump operates but does not pressurise
Diagnostics:
Problem-solving:
Sealing fault in the couplings
Check the tightening of the couplings. (the
knurled parts must be tightened by hand)
The hose is damaged
Fold the free end of the hose and check the
pressurisation; repeat the operation by
reversing the end connected to the controller.
The checker is damaged (in a fall for example)
Check the operation of the controller by
screwing a vehicle valve stopper in place of the
hose. If the controller does not pressurise
return it to VIRAX After-Sales Service.
Guarantee
The controller is guaranteed for 2 years except for the battery and the hose.
Damage caused by leakage of a non-compliant battery is excluded from the guarantee.
Spare parts
Designation
Code
Hose
752964
1/2 GAZ coupling
752965
7/8 GAZ coupling
752966
M20-150 coupling
752967
Bag
752968
Hose ends (2)
752969
Содержание 262080