background image

Maintenance

3

Section 3

Maintenance 

3.1 Cartridge Replacement

Replace cartridge when there is a noticeable drop in water flow at the faucet or tap.

Procedure:

Section 4

Replacement Parts

Parts

Description

FB-34PR-PS

FB-34PR

FB2-34PR

FC-34PR-PS

FC-34V

FB2-34PR

Sediment

 AWP110

 AWP110

AWP110-2

Taste/Odour

 AWP117 or C-01

 AWP117 or C-01

C-02

O-ring

OR-4

OR-6

OR-8

1

•   

Shut off inlet and outlet 
valves.

•   

Depress pressure relief 
button on top of filter head to 
relieve pressure in filter.

2

•   

Unscrew sump from outer 
head and remove cartridge 
emptying water from sump.

3

•   

Clean and inspect all 
components. 

•   

Lubricate O-rings with a light 
coating of a silicone based 
lubricant. Replace O-ring seal 
if there is visible damage.

•   

Install new VIQUA cartridge 
into sump. 

Note: 

VIQUA cartridges are 

designed and manufactured 
to provide the best possible 
performance. Use of non-
VIQUA cartridges may result 
in system failure.

4

•   

Place lubricated O-ring on the 

sump. 

•   

Hand-tighten sump firmly 

onto the head until a definite 
stop is felt and the cartridge 
is sealed. 

Note: 

Do not overtighten the 

sump.

•   

Turn on inlet valve and 
depress pressure relief 
button until air is purged from 
filter. 

•   

Release button and turn on 
outlet valve.

Отзывы: