Maintenance
3
Section 3
Maintenance
3.1 Cartridge Replacement
Replace cartridge when there is a noticeable drop in water flow at the faucet or tap.
Procedure:
Section 4
Replacement Parts
Parts
Description
FB-34PR-PS
FB-34PR
FB2-34PR
FC-34PR-PS
FC-34V
FB2-34PR
Sediment
AWP110
AWP110
AWP110-2
Taste/Odour
AWP117 or C-01
AWP117 or C-01
C-02
O-ring
OR-4
OR-6
OR-8
1
•
Shut off inlet and outlet
valves.
•
Depress pressure relief
button on top of filter head to
relieve pressure in filter.
2
•
Unscrew sump from outer
head and remove cartridge
emptying water from sump.
3
•
Clean and inspect all
components.
•
Lubricate O-rings with a light
coating of a silicone based
lubricant. Replace O-ring seal
if there is visible damage.
•
Install new VIQUA cartridge
into sump.
Note:
VIQUA cartridges are
designed and manufactured
to provide the best possible
performance. Use of non-
VIQUA cartridges may result
in system failure.
4
•
Place lubricated O-ring on the
sump.
•
Hand-tighten sump firmly
onto the head until a definite
stop is felt and the cartridge
is sealed.
Note:
Do not overtighten the
sump.
•
Turn on inlet valve and
depress pressure relief
button until air is purged from
filter.
•
Release button and turn on
outlet valve.