background image

8

©

2005 

Directed Electronics, Inc.

H1/8 GREEN (-) door trigger input
Most vehicles use negative door trigger circuits. Connect the GREEN wire to a wire showing
ground when any door is opened. When connecting to newer model vehicles there is generally a
need to use individual door triggers. See DirectFax document 1076 for wiring instructions. This
wire will report Zone 3.

N

NO

OTTEE: If using a door trigger wire that has a delay, Advanced Menu 2, feature 6, or the 998T Bitwriter

®

can be used to turn Bypass Notification off.

H1/9 BLACK/WHITE high current output from on-board domelight supervision relay
Connect this wire directly to the domelight circuit in the vehicle. The on-board relay will drive
circuits up to 20 amperes. The polarity of this output is determined by the connection of the input
wire H2/A in the Relay Harness.

N

NO

OTTEE: If the input wire H2/A is not connected, there will be no output on this wire.

H1/10 WHITE/BLUE 200 mA (-) channel 3 output
This wire provides a (-) 200 mA output whenever the transmitter button(s) controlling Channel 3

is pressed. This output can be programmed to provide the following types of output (see 

System

Features Learn Routine section of this guide):

A vvaalliiddiittyy output will send a signal as long as the transmission is received.

A llaattcchheedd output will send a signal continuously when the Channel 3 button(s) is pressed and
released. The signal will continue until channel three is pressed again.

A  llaattcchheedd//rreesseett   w

wiitthh   iiggnniittiioonn output works similar to the latched output, but will also reset

(output will stop) when the ignition is turned on and then off.

A  3300   ((6600,,   9900))   sseeccoonndd   ttiim

meedd   output will send a signal for 30 seconds when channel three is

pressed. This output can be shut off during the 30-second period by pressing Channel 3 again.
The Bitwriter

TM

can program from 1 to 90 seconds.

R

Reem

moottee  ssttaarrtt  output (refer to System Features Menu description for additional information).

Содержание SmartStart 3000 Series

Страница 1: ...s st ta al ll la at ti io on n G Gu ui id de e NOTE This product is intended for installation by a professional installer only Any attempt to install this product by any person other than a trained pr...

Страница 2: ...are all Trademarks or Registered Trademarks of Directed Electronics Inc The Bitwriter p n 998T requires chip version 1 4 or newer to program this unit w ww ww w d di ir re ec ct te ec ch hs s c co om...

Страница 3: ...lug 15 Mounting the Transceiver Antenna 15 Optional Sensors 4 Pin White Plug 16 P Pr ro og gr ra am mm mi in ng g J Ju um mp pe er r 1 16 6 Light Flash Jumper 17 B By yp pa as ss si in ng g S Se en ns...

Страница 4: ...l le e R Re ec co ov ve er ry y S Sy ys st te em m V VR RS S 3 35 5 N Nu ui is sa an nc ce e P Pr re ev ve en nt ti io on n C Ci ir rc cu ui it tr ry y 3 36 6 R Ra ap pi id d R Re es su um me e L Lo o...

Страница 5: ...ut is often used for trunk release Whenever the button s controlling channel two is pressed for 1 5 seconds this output is activated and will stay activated as long as the transmission continues Use a...

Страница 6: ...int you connect the control module s BLACK ground wire H1 4 YELLOW ignition input Connect this wire to the 12 volts ignition wire This wire must show 12 volts with the key in RUN position and during c...

Страница 7: ...dvanced Menu 2 feature 6 or the 998T Bitwriter can be used to turn Bypass Notification off H1 7 BLUE instant trigger input This input will respond to a negative input with an instant trigger It is ide...

Страница 8: ...10 WHITE BLUE 200 mA channel 3 output This wire provides a 200 mA output whenever the transmitter button s controlling Channel 3 is pressed This output can be programmed to provide the following types...

Страница 9: ...ground as long as the system is armed This output ceases as soon as the system is disarmed It can supply up to 500 mA of current NOTE A dual diode harness assembly is provided Viper model only for Eur...

Страница 10: ...retained accessory output N NO OT TE E An additional relay not supplied is required for most applications Connect this wire to the accessory wire in the vehicle that powers the accessories in the vehi...

Страница 11: ...o be used like a siren output with arm disarm chirps Refer to System Features Menus 3 feature 2 in the manual for additional information H2 8 LIGHT GREEN BLACK factory disarm output This wire sends a...

Страница 12: ...ic power door lock systems drawing 30 amps or less It can also drive aftermarket actuators directly Some vehicles require that an aftermarket actuator be added to the driver s door to allow system con...

Страница 13: ...a normally open or normally closed circuit by connecting the desired side of the three wire immobilizer Locate the starter wire then cut it and make connections as described in the following diagram C...

Страница 14: ...n with a RED LED Valet Program Button 2 Pin BLUE Plug The Valet Program button should be accessible from the driver s seat It plugs into the BLUE port on the side of the unit Since the system features...

Страница 15: ...ble to the vehicle s operator The best location for the transceiver antenna is centered high on either the front or rear windshield For optimal range the antenna should be mounted vertically It can be...

Страница 16: ...an 0 8 seconds will trigger full alarm sequence and report Zone 4 or Zone 7 for multiplex input N NO OT TE E The ground for the optional sensors is now controlled by the GWA Programming Jumper Parking...

Страница 17: ...he vehicle Anytime an auxiliary channel output is used sensor inputs are bypassed until 5 seconds after the output ceases Anytime from the start of the output until the end of the bypass period ground...

Страница 18: ...oo or r The H1 8 GREEN wire or the H1 6 VIOLET wire must be connected 2 I Ig gn ni it ti io on n Turn the ignition on then back off The H1 4 YELLOW wire must be connected 3 S Se el le ec ct t a a M M...

Страница 19: ...ss and release the Valet Program button the number of times necessary to advance from the feature you just programmed to the next one you want to program 2 Then press the Valet Program button once mor...

Страница 20: ...pulse setting the siren will chirp three times Feature One Chirp Two Chirp Number Setting Setting 1 1 Active arming Passive arming 1 2 Chirps ON Chirps OFF 1 3 Ignition controlled door locks ON Igniti...

Страница 21: ...Valet button input 1 pulse Valet button input 2 5 pulses 2 6 Bypass Notification ON Bypass Notification OFF 2 7 Enhanced Domelight Control Full door only ignition only Off 2 8 Single unlock pulse Doub...

Страница 22: ...n Factory Disarm with Channel 2 Off 3 4 Ground When Armed in Valet On Ground When Armed in Valet Off 3 5 Channel 3 Validity latched latched reset with ignition 30 second 60 second 90 second timed remo...

Страница 23: ...IVE PASSIVE LOCKING If passive arming is selected in menu item 1 1 then the system can be programmed to either lock the doors when passive arming occurs or only lock the doors when the system is armed...

Страница 24: ...the user Refer to the Owner s Guide for additional description 1 11 CODE HOPPING ON OFF The system uses a mathematical formula to change its code each time the transmitter and receiver communicate Th...

Страница 25: ...remain in the armed state 2 2 SIREN DURATION 30 60 SECONDS It is possible to program the unit to sound for 30 or 60 seconds during the triggered sequence Some states have laws regulating how long a s...

Страница 26: ...bypass notification chirp if active When programmed OFF no bypass notification chirps will be generated if zone 3 is active during arming 2 7 ENHANCED DOMELIGHT CONTROL This feature has four possible...

Страница 27: ...a normally closed or normally open pin switch 2 13 DUAL SENSOR TRIGGER ON OFF When programmed On any two sensors zones 2 4 7 need to be triggered within 1 second of each other to trigger the alarm si...

Страница 28: ...nd the Factory Alarm Disarm will output immediately after receiving a remote start operation Remote start OFF report When programmed on and ground on zone 1 ceases and the system will Zone 3 will moni...

Страница 29: ...ferent transmitter codes in memory Use the following learn routine to add transmitters to the system or to change button assignments if desired If the system was previously programmed using the 998T B...

Страница 30: ...ill revert to the default settings This is useful in cases where one of the customer s transmitters is lost or stolen This will erase any lost or stolen transmitters from the system s memory It can al...

Страница 31: ...earn Routine will program the transmitter buttons to the following configuration Standard Configuration 2 Way LED Remote When programmed for standard configuration the transmitter buttons are assigned...

Страница 32: ...hirp 2 times for each step increased in adjustment When the shock sensor adjustment reaches maximum sensitivity the siren will emit 2 short chirps and then 1 long chirp 2 D De ec cr re ea as se e S Se...

Страница 33: ...adjustment at any time while in adjustment mode 1 Simultaneously press the and buttons 2 The system will emit 3 chirps to indicate the sensor has been reset to level 10 3 The system returns to shock...

Страница 34: ...VIOLET 4 Multiplexed Input Inputs shorter than 0 8 seconds will trigger a Warning Zone response while inputs longer than 0 8 seconds will instantly trigger the full alarm sequence 5 Two stage similar...

Страница 35: ...d the unit The LED will flash for one minute or until the ignition is turned off N NO OT TE E The Warning Zone triggers are not stored to memory and will not be reported Multi Level Security Arming Mu...

Страница 36: ...It is connected to an accessory circuit Sensors don t trigger the alarm Has the NPC system been triggered If so you will hear five chirps when disarming To check this turn the ignition key on and off...

Страница 37: ...impact sensor caused the trigger the sensor may be detecting the door opening Reducing the sensitivity or relocating the sensor can often solve this problem If the LED indicates that the door caused t...

Страница 38: ...38 2005 Directed Electronics Inc...

Страница 39: ...d LIGHT GREEN BLACK Factory Disarm Output LIGHT BROWN Horn Honk Output VIOLET BLACK CH4 Output WHITE BLACK CH5 Output GRAY BLACK CH6 Output ORANGE BLACK Retained Accessory Output GREY Hood Pin Input Z...

Отзывы: