2-9 DOUBLE/SINGLE PULSE LOCK: Some vehicles require two pulses on a single wire to lock
the doors. When the double pulse lock feature is turned on, the GREEN/BLACK H2/C wire will
supply two pulses instead of a single pulse. This makes it possible to directly interface with double
pulse vehicles without any extra parts.
2-10 COMFORT CLOSURE: The system can be programmed to close the windows when the
system is armed. A 20-second output starts 200mS after the last lock
pulse. The Comfort
Closure output will be canceled if the unlock
button is pressed. If programmed, the lock output
wire will provide this function.
NOTE: Comfort Closure is deleted if one-time bypass is activated.
2-11 IMMOBILIZER NORMALLY CLOSED/NORMALLY OPEN: When programmed to the
Normally closed position, the car can be started if power to the alarm is removed for service.
2-12 HOOD TRIGGER NORMALLY CLOSED/NORMALLY OPEN: To program the unit for
either a normally closed or normally open pin switch.
2-13 DUAL SENSOR TRIGGER ON/OFF: When programmed On any two sensors (zones 2, 4,
7) need to be triggered within 1-second of each other to trigger the alarm/siren. When programmed
Off each sensor will trigger the alarm/siren independently.
NOTE: When On Multi-Level Arming is defeated.
2-14 HIGH SECURITY DISARM ON/OFF: When programmed On the system will silence the
siren on the first press of the unlock button and disarm/unlock on the second press of the unlock
button. When programmed Off (or within 5-seconds of alarm triggering when programmed On)
the system will disarm and unlock on the first press of the unlock button.
Menu #3 - Advanced Features
3-1 HORN (PULSED)/HORN (CONSTANT): Program for either a pulsed output or a continu-
ous output when triggered.
3-2 HORN FUNCTION (FULL ALARM ONLY)/SIREN FUNCTION (20mS, 30mS, 40mS,
50mS): Program for output when the alarm is fully triggered or as the siren (arming/disarming and
warnaway and full trigger with timing options).
3-3 FACTORY DISARM WITH CHANNEL 2 (ON)/FACTORY DISARM WITH CHANNEL
2 (OFF): The factory alarm disarm wire sends out a pulse when activating channel 2 output.