1-8 FORCED PASSIVE ARMING ON/OFF: To use this feature, passive arming must be selected
in menu item 1-1. When turned on, forced passive arming will ensure that the system will passively
arm, even if a zone is left open or invalid. Forced passive arming occurs one hour after the ignition
is turned off.
1-9 AUTOMATIC ENGINE DISABLE (AED) ON/OFF: AED is a full-time, passive starter
disable that works independently of the security system. When turned on, the starter immobilizer
circuit will go active 30 seconds after the ignition is turned off. The LED will flash at half its normal
rate when the ignition is turned off to indicate that AED is active and will interrupt the starter in
30 seconds. AED does not occur in Valet mode and can be bypassed using the emergency override
procedure. The transmitter can also be used to disarm AED.
1-10 VEHICLE RECOVERY SYSTEM: If Vehicle Recovery System (VRS
®
®
) is programmed to the
ON setting, VRS
®
®
can be activated by the user. Refer to the
Owner’s Guide for additional description.
1-11 CODE-HOPPING™ ON/OFF: The system uses a mathematical formula to change its code
each time the transmitter and receiver communicate. This makes the group of bits or “word” from
the transmitter very long. The longer the word is, the easier it is to block its transmission to the unit.
Disabling the Code-Hopping™ feature lets the receiver ignore the Code-Hopping™ part of the
transmitted word. As a result, the unit may have better range with Code-Hopping™ off.
Menu #2 - Advanced Features
2-1 MULTI-LEVEL ARMING: The system can be programmed to bypass selected zones or
groups of zones when armed or to have multi-level arming off. The parking light flashes provide the
indication for the zones or groups selected to be bypassed.
Progressive Multi-Level Arming
After arming, immediately press the ARM
button again to enter multi-level arming.
Press
button once
2 light flashes
Zone 2 bypassed
Press
button twice
3 light flashes
Zone 4 bypassed
Press
button three times 4 light flashes
Zone 7 bypassed
Press
button four times 5 light flashes
Zone 2 and 4 bypassed
Press
button five times
6 light flashes
Zone 2 and 7 bypassed