INSTRUCTION FOR USE
ENGLISH
18
TANK EMPTYING
Recovery water tank emptying
When the Multifunction display (47, Figure 3) show ERROR24
and the recovery tank full indicator (48, Figure3) is turned on. It
indicates the recovery tank (C, Figure15) is full, the vacuum motor
cannot longer dry the floor. Empty the recovery tank as following
steps:
1.
Stop the machine.
2.
Lift the brush/pad-holder deck and the squeegee by pressing
the one-button start (51, Figure 3).
3.
Drive the machine to the appointed disposal area.
4.
Empty the recovery water tank with the hose (D, Figure 15).
Then, rinse the tank (C, Figure 15) with clean water.
CAUTION!
When draining the wastewater, the hold the drain
hose high, and fold over the top section to avoid
spilling onto the operator.
Solution/clean water tank emptying
1.
Empty the solution tank with the outlet cover (A, Figure 15). After working, rinse the tank with clean water.
AFTER USING THE MACHINE
After working, before leaving the machine:
1.
Remove the brushes/pad-holders by pressing the release left button (56, Figure 3) and clean them.
2.
Empty the tanks (B and C, Figure 15) as shown in the previous paragraph.
3.
Perform the daily maintenance procedures (see the Maintenance chapter).
4.
Store the machine in a clean and dry place, with the brushes/ pad-holders and the squeegee lifted or removed.
5.
Use the recovery tank lid support to keep the lid open. This will help prevent odors from building up inside.
MACHINE STORAGE DURING LONG INACTIVITY
If the machine is not going to be used for more than 30 days, proceed as follows:
1.
Perform the procedures shown in After Using the machine paragraph.
2.
Disconnect the battery connector.
Figure 14
Figure 15